Non-apposed stent graft size placement reduces edge stenosis in the peripheral outflow vein of hemodialysis patients
In hemodialysis patients, nonapposed stent placements showed better TLPP rates, especially in the in-valve and in-aneurysm patient subgroups, which is contrary to the manufacturer's instructions for use and the results of some previosuly published articles.
Authors
- Huei‐Lung Liang (ORCID: https://orcid.org/0000-0002-9983-0535)
- Chia‐Ling Chiang (ORCID: https://orcid.org/0000-0001-5759-6173)
- I-Li Su
- Matt Chiung-Yu Chen (ORCID: https://orcid.org/0000-0003-0243-2328)
Institutions
- Chang Gung Memorial Hospital (TW)
- Yuan's General Hospital (TW)
- Kaohsiung Veterans General Hospital (TW)
Publication Details
- Journal
- Journal of Vascular Surgery
- Published
- 2025-09-01
- DOI
- https://doi.org/10.1016/j.jvs.2025.08.049
- Primary Topic
- Central Venous Catheters and Hemodialysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00