Magnetic bead electrochemical sandwich assay (MBESA) for the inflammatory cytokine interleukin-1β in fetal membrane on-a-chip studies and placental macrophages

Preterm birth (PTB), triggered by preterm premature rupture of membranes (PPROM), remains a global health challenge, often linked to infections like chorioamnionitis. Existing biomarker detection methods, such as ELISAs, are limited by time, cost, and reagent requirements. There is a significant demand for new analytical techniques that identify PTB biomarkers, such as the inflammatory cytokine interleukin-1β (IL-1β), within biological models. In this work, we have quantified IL-1β with our newly developed magnetic bead electrochemical sandwich assay (MBESA), an alternative to traditional ELISAs. We have utilized a fetal membrane organ on-a-chip (FMOC) to mimic the physiological functions of the human fetal membranes during bacterial infections in vitro . The MBESA was optimized to detect IL-1β levels present within a FMOC and lipopolysaccharides (LPS)-infected cell cultures. We present the design of the MBESA, highlighting the high sensitivity of an electrochemical technique and the application of the FMOC in reproductive research. The MBESA was able to reproducibly detect standard IL-1β levels in the physiological ranges of 10 pg/mL to 600 pg/mL. Significant differences were observed in LPS-treated and untreated macrophages samples, but there was no significant difference between the MBESA and ELISA methods when examining LPS-treated and untreated macrophages samples. The MBESA’s reduced reagent use, faster results, and compatibility with organ on-a-chip systems suggest its potential for integration into point-of-care diagnostic tools targeting inflammation-driven PTB. • MBESA detects IL-1β with high sensitivity and reduced reagent requirements • FMOC replicates fetal membrane inflammation for in vitro cytokine analysis • MBESA shows strong agreement with ELISA for LPS-treated macrophage samples • FMOC and MBESA support point-of-care diagnostics for PTB biomarkers

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-09-10
DOI
https://doi.org/10.1016/j.snb.2025.138724
Citations
1
Primary Topic
Reproductive System and Pregnancy
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic bead electrochemical sandwich assay (MBESA) for the inflammatory cytokine interleukin-1β in fetal membrane on-a-chip studies and placental macrophages

Jacklyn E. Martin, Olivia E. Owens, David E. Cliffel, Hannah A. Richards
1 citations
Sensors and Actuators B Chemical
Reproductive System and Pregnancy
0.80
article

Magnetic bead electrochemical sandwich assay (MBESA) for the inflammatory cytokine interleukin-1β in fetal membrane on-a-chip studies and placental macrophages

Jacklyn E. Martin, Olivia E. Owens, David E. Cliffel, Hannah A. Richards
article en
1 citations

Abstract

Preterm birth (PTB), triggered by preterm premature rupture of membranes (PPROM), remains a global health challenge, often linked to infections like chorioamnionitis. Existing biomarker detection methods, such as ELISAs, are limited by time, cost, and reagent requirements. There is a significant demand for new analytical techniques that identify PTB biomarkers, such as the inflammatory cytokine interleukin-1β (IL-1β), within biological models. In this work, we have quantified IL-1β with our newly developed magnetic bead electrochemical sandwich assay (MBESA), an alternative to traditional ELISAs. We have utilized a fetal membrane organ on-a-chip (FMOC) to mimic the physiological functions of the human fetal membranes during bacterial infections in vitro . The MBESA was optimized to detect IL-1β levels present within a FMOC and lipopolysaccharides (LPS)-infected cell cultures. We present the design of the MBESA, highlighting the high sensitivity of an electrochemical technique and the application of the FMOC in reproductive research. The MBESA was able to reproducibly detect standard IL-1β levels in the physiological ranges of 10 pg/mL to 600 pg/mL. Significant differences were observed in LPS-treated and untreated macrophages samples, but there was no significant difference between the MBESA and ELISA methods when examining LPS-treated and untreated macrophages samples. The MBESA’s reduced reagent use, faster results, and compatibility with organ on-a-chip systems suggest its potential for integration into point-of-care diagnostic tools targeting inflammation-driven PTB. • MBESA detects IL-1β with high sensitivity and reduced reagent requirements • FMOC replicates fetal membrane inflammation for in vitro cytokine analysis • MBESA shows strong agreement with ELISA for LPS-treated macrophage samples • FMOC and MBESA support point-of-care diagnostics for PTB biomarkers

Sensors and Actuators B ChemicalVol. 446
Lebanon Valley College (US), Vanderbilt University (US)
Openalex Percentile: Top 24%
Reproductive System and Pregnancy
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.