Influence mechanism of cable terminal on airflow and leeward pollution distribution of high-speed train roof post insulator

The airflow around the high-speed train roof insulator modifies the distribution of fan-shaped, non-uniform contamination on the umbrella skirts, and the flashover voltage decreases as surface contamination becomes more uneven. Wind tunnel tests at 55 m/s show that the presence of a cable terminal significantly alters the leeward pollution distribution compared with a single post insulator. To investigate the underlying mechanism, an Euler–Euler two-phase flow model including both the cable terminal and the insulator was developed. Simulations reveal that airflow upwash and downwash on the leeward side of the insulator modify spanwise and streamwise flow patterns and the passage width between umbrella skirts, thereby shifting the boundaries of heavily polluted zones. Pollution accumulation experiments of 3 D-printed scale models confirmed the predictive capability of this approach. These results clarify how nearby structures influence airflow–pollution interactions and provide guidance for evaluating leeward pollution characteristics, optimizing insulator layouts, and understanding flashover behavior under non-uniform contamination conditions.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-09-01
DOI
https://doi.org/10.1063/5.0276983
Primary Topic
Aerodynamics and Fluid Dynamics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence mechanism of cable terminal on airflow and leeward pollution distribution of high-speed train roof post insulator

Caiya Chen, Liang Mao, Shuyao Zhang, Jianqiao Ma
Physics of Fluids
Aerodynamics and Fluid Dynamics Research
article

Influence mechanism of cable terminal on airflow and leeward pollution distribution of high-speed train roof post insulator

Caiya Chen, Liang Mao, Shuyao Zhang, Jianqiao Ma
article en

Abstract

The airflow around the high-speed train roof insulator modifies the distribution of fan-shaped, non-uniform contamination on the umbrella skirts, and the flashover voltage decreases as surface contamination becomes more uneven. Wind tunnel tests at 55 m/s show that the presence of a cable terminal significantly alters the leeward pollution distribution compared with a single post insulator. To investigate the underlying mechanism, an Euler–Euler two-phase flow model including both the cable terminal and the insulator was developed. Simulations reveal that airflow upwash and downwash on the leeward side of the insulator modify spanwise and streamwise flow patterns and the passage width between umbrella skirts, thereby shifting the boundaries of heavily polluted zones. Pollution accumulation experiments of 3 D-printed scale models confirmed the predictive capability of this approach. These results clarify how nearby structures influence airflow–pollution interactions and provide guidance for evaluating leeward pollution characteristics, optimizing insulator layouts, and understanding flashover behavior under non-uniform contamination conditions.

Physics of FluidsVol. 37(9)
Lanzhou Jiaotong University (CN), Shanghai Electric (China) (CN)
Openalex Percentile: Top 67%
Aerodynamics and Fluid Dynamics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence mechanism of cable terminal on airflow and leeward pollution distribution of high-speed train roof post insulator — Caiya Chen, Liang Mao, et al. · Physics of Fluids (2025) | TGRS Research Map | TGRS