A Cost‐Effective Hydrogel‐Based Electrochemical Platform for Uric Acid Detection in Synthetic Urine

This study introduces, for the first time, a novel voltammetric strategy based on integrating a stencil‐printed electrode (StPE) with a hydrogel (HG) serving as the electrolytic medium. The electrode was fabricated using a laboratory‐made conductive ink composed of graphite (as the conductive material), glass varnish (as the polymeric binder), and an acetate sheet (as the substrate). The HG selected for this study consisted of sodium polyacrylate, a polymer commonly used for plant irrigation and decorative purposes due to its high water‐retention capacity. The StPE sensors were characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), while the HG was thoroughly characterized using scanning electron microscopy (SEM), Fourier‐transform infrared spectroscopy (FTIR), and energy‐dispersive X‐ray spectroscopy (EDX). Additionally, the kinetic parameters of HG absorption were evaluated by fixing the hydration time at 6 h. As a proof of concept, uric acid (UA), a clinically relevant biomarker, was selected as the model analyte. A differential pulse voltammetry (DPV) method was developed to monitor UA in synthetic urine samples. The sensor exhibited a linear response in the concentration range of 2.0–10.0 µmol L −1 , with excellent detectability (limit of detection = 0.146 µmol L − 1 ). The method also demonstrated good precision (RSD < 4.4%) and accuracy, with recovery rates ranging from 94% to 105% in spiked samples. The sustainable characteristics of the StPE sensor, combined with its effective performance in the HG medium, highlight the potential of this platform for electrochemical analysis of other clinically, environmentally, and forensically relevant analytes, offering broad opportunities for future innovations.

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2025-09-01
DOI
https://doi.org/10.1002/elan.70053
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Cost‐Effective Hydrogel‐Based Electrochemical Platform for Uric Acid Detection in Synthetic Urine

José Pedro Rocha, Cassiano Cunha de Souza, Wallace Burger Veríssimo de Oliveira, Gabriela C. da Silva et al.
Electroanalysis
Electrochemical sensors and biosensors
article

A Cost‐Effective Hydrogel‐Based Electrochemical Platform for Uric Acid Detection in Synthetic Urine

José Pedro Rocha, Cassiano Cunha de Souza, Wallace Burger Veríssimo de Oliveira, Gabriela C. da Silva, Raylla Santos Oliveira, Thalles Pedrosa Lisboa, Renato Camargo Matos, Maria Auxiliadora Costa Matos
article en

Abstract

This study introduces, for the first time, a novel voltammetric strategy based on integrating a stencil‐printed electrode (StPE) with a hydrogel (HG) serving as the electrolytic medium. The electrode was fabricated using a laboratory‐made conductive ink composed of graphite (as the conductive material), glass varnish (as the polymeric binder), and an acetate sheet (as the substrate). The HG selected for this study consisted of sodium polyacrylate, a polymer commonly used for plant irrigation and decorative purposes due to its high water‐retention capacity. The StPE sensors were characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), while the HG was thoroughly characterized using scanning electron microscopy (SEM), Fourier‐transform infrared spectroscopy (FTIR), and energy‐dispersive X‐ray spectroscopy (EDX). Additionally, the kinetic parameters of HG absorption were evaluated by fixing the hydration time at 6 h. As a proof of concept, uric acid (UA), a clinically relevant biomarker, was selected as the model analyte. A differential pulse voltammetry (DPV) method was developed to monitor UA in synthetic urine samples. The sensor exhibited a linear response in the concentration range of 2.0–10.0 µmol L −1 , with excellent detectability (limit of detection = 0.146 µmol L − 1 ). The method also demonstrated good precision (RSD < 4.4%) and accuracy, with recovery rates ranging from 94% to 105% in spiked samples. The sustainable characteristics of the StPE sensor, combined with its effective performance in the HG medium, highlight the potential of this platform for electrochemical analysis of other clinically, environmentally, and forensically relevant analytes, offering broad opportunities for future innovations.

ElectroanalysisVol. 37(9)
Universidade Federal de Juiz de Fora (BR), Universidade Federal da Grande Dourados (BR)
Openalex Percentile: Top 77%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.