[ <sup>99m</sup> Tc]Tc-Sestamibi/[ <sup>99m</sup> Tc]NaTcO <sub>4</sub> Subtraction SPECT of Parathyroid Glands Using Analysis of Principal Components

The aim of the study was to validate a new method for semiautomatic subtraction of [<sup>99m</sup>Tc]Tc-sestamibi and [<sup>99m</sup>Tc]NaTcO<sub>4</sub> SPECT 3-dimensional datasets using principal component analysis (PCA) against the results of parathyroid surgery and to compare its performance with an interactive method for visual comparison of images. We also sought to identify factors that affect the accuracy of lesion detection using the two methods. <b>Methods:</b> Scintigraphic data from [<sup>99m</sup>Tc]Tc-sestamibi and [<sup>99m</sup>Tc]NaTcO<sub>4</sub> SPECT were analyzed using semiautomatic subtraction of the 2 registered datasets based on PCA applied to the region of interest including the thyroid and an interactive method for visual comparison of the 2 image datasets. The findings of both methods were compared with those of surgery. Agreement with surgery was assessed with respect to the lesion quadrant, affected side of the neck, and the patient positivity regardless of location. <b>Results:</b> The results of parathyroid surgery and histology were available for 52 patients who underwent [<sup>99m</sup>Tc]Tc-sestamibi/[<sup>99m</sup>Tc]NaTcO<sub>4</sub> SPECT. Semiautomatic image subtraction identified the correct lesion quadrant in 46 patients (88%), the correct side of the neck in 51 patients (98%), and true pathologic lesions regardless of location in 51 patients (98%). Visual interactive analysis identified the correct lesion quadrant in 44 patients (85%), correct side of the neck in 49 patients (94%), and true pathologic lesions regardless of location in 50 patients (96%). There was no significant difference between the results of the 2 methods (<i>P</i> > 0.05). The factors supporting lesion detection were accurate positioning of the patient on the camera table, which facilitated subsequent image registration of the neck, and, after excluding ectopic parathyroid glands, focusing detection on the thyroid ROI. <b>Conclusion:</b> The results of semiautomatic subtraction of [<sup>99m</sup>Tc]Tc-sestamibi/[<sup>99m</sup>Tc]NaTcO<sub>4</sub> SPECT using PCA had good agreement with the findings from surgery as well as the visual interactive method, comparable to the high diagnostic accuracy of [<sup>99m</sup>Tc]Tc-sestamibi/[<sup>123</sup>I]NaI subtraction scintigraphy and [<sup>18</sup>F]fluorocholine PET/CT reported in the literature. The main advantages of semiautomatic subtraction are minimum user interaction and automatic adjustment of the subtraction weight. Principal component images may serve as optimized input objects, potentially useful in machine-learning algorithms aimed at fully automated detection of hyperfunctioning parathyroid glands.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine Technology
Published
2025-09-09
DOI
https://doi.org/10.2967/jnmt.125.270082
Primary Topic
Parathyroid Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[ 99m Tc]Tc-Sestamibi/[ 99m Tc]NaTcO 4 Subtraction SPECT of Parathyroid Glands Using Analysis of Principal Components

David Zogala, Irena Maříková, Martin Šámal, Jean‐Noël Talbot et al.
Journal of Nuclear Medicine Technology
Parathyroid Disorders and Treatments
article

[ 99m Tc]Tc-Sestamibi/[ 99m Tc]NaTcO 4 Subtraction SPECT of Parathyroid Glands Using Analysis of Principal Components

David Zogala, Irena Maříková, Martin Šámal, Jean‐Noël Talbot, Jiří Trnka, Soňa Balogová, Václav Ptáčník, P Libánský, Ivan Raška
article en

Abstract

The aim of the study was to validate a new method for semiautomatic subtraction of [<sup>99m</sup>Tc]Tc-sestamibi and [<sup>99m</sup>Tc]NaTcO<sub>4</sub> SPECT 3-dimensional datasets using principal component analysis (PCA) against the results of parathyroid surgery and to compare its performance with an interactive method for visual comparison of images. We also sought to identify factors that affect the accuracy of lesion detection using the two methods. <b>Methods:</b> Scintigraphic data from [<sup>99m</sup>Tc]Tc-sestamibi and [<sup>99m</sup>Tc]NaTcO<sub>4</sub> SPECT were analyzed using semiautomatic subtraction of the 2 registered datasets based on PCA applied to the region of interest including the thyroid and an interactive method for visual comparison of the 2 image datasets. The findings of both methods were compared with those of surgery. Agreement with surgery was assessed with respect to the lesion quadrant, affected side of the neck, and the patient positivity regardless of location. <b>Results:</b> The results of parathyroid surgery and histology were available for 52 patients who underwent [<sup>99m</sup>Tc]Tc-sestamibi/[<sup>99m</sup>Tc]NaTcO<sub>4</sub> SPECT. Semiautomatic image subtraction identified the correct lesion quadrant in 46 patients (88%), the correct side of the neck in 51 patients (98%), and true pathologic lesions regardless of location in 51 patients (98%). Visual interactive analysis identified the correct lesion quadrant in 44 patients (85%), correct side of the neck in 49 patients (94%), and true pathologic lesions regardless of location in 50 patients (96%). There was no significant difference between the results of the 2 methods (<i>P</i> > 0.05). The factors supporting lesion detection were accurate positioning of the patient on the camera table, which facilitated subsequent image registration of the neck, and, after excluding ectopic parathyroid glands, focusing detection on the thyroid ROI. <b>Conclusion:</b> The results of semiautomatic subtraction of [<sup>99m</sup>Tc]Tc-sestamibi/[<sup>99m</sup>Tc]NaTcO<sub>4</sub> SPECT using PCA had good agreement with the findings from surgery as well as the visual interactive method, comparable to the high diagnostic accuracy of [<sup>99m</sup>Tc]Tc-sestamibi/[<sup>123</sup>I]NaI subtraction scintigraphy and [<sup>18</sup>F]fluorocholine PET/CT reported in the literature. The main advantages of semiautomatic subtraction are minimum user interaction and automatic adjustment of the subtraction weight. Principal component images may serve as optimized input objects, potentially useful in machine-learning algorithms aimed at fully automated detection of hyperfunctioning parathyroid glands.

Journal of Nuclear Medicine TechnologyVol. 53(4)
Charles University (CZ), Institute for Postgraduate Medical Education (CZ), University Hospital in Motol (CZ), Institut National des Sciences de l'Univers (FR), General University Hospital in Prague (CZ)
Openalex Percentile: Top 74%
Parathyroid Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.