Structurally Engineered All-Polymeric Microneedle Sensor for Highly Sensitive and Real-Time Monitoring of Glucose in Interstitial Fluids

Diabetes mellitus (DM) is a chronic metabolic disorder characterized by persistent hyperglycemia with multiple clinical manifestations and complications, such as cardiovascular disease, kidney dysfunction, retinal impairment, and peripheral neuropathy. Continuous and minimally invasive glucose monitoring is essential for effective DM management. Microneedles (MNs)-based sensing platforms offer a promising solution; however, conventional polymeric MNs suffer from limited electrochemical sensitivity due to their insufficient electroactive surface area and inefficient loading of catalytic and enzymatic components. Herein, we present a fully polymeric, high-sensitive glucose sensor based on structurally engineered mushroom-shaped MNs. The MNs were fabricated from a biocompatible composite of triethylene glycol dimethacrylate (TEGDMA) and diurethane dimethacrylate (DUDMA) and further functionalized with poly(3,4-ethylenedioxythiophene)/tosylate (PEDOT/Tos) to enhance electron transport capabilities. A capillary-driven dip-coating process led to the deposition of Pt nanoparticles (Pt NPs)/PEDOT:PSS composite ink into the neck region of the MNs, resulting in localized loading of electrocatalytic material and a significant increase in electrochemical activity. Consequently, the mushroom-shaped MNs exhibited a 12.6-fold enhancement in current response to glucose compared to conical MNs, while maintaining a linear dynamic range between 2 and 20 mM. Furthermore, in vivo validation demonstrated real-time glucose tracking with strong agreement to commercial glucometer readings, and Clarke error grid analysis verified clinical accuracy. Collectively, these results underscore the utility of structural engineering in polymeric MNs to achieve reliable, continuous glucose monitoring for next-generation diabetes care.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-09-10
DOI
https://doi.org/10.1021/acssensors.5c02073
Citations
2
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
1.58
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structurally Engineered All-Polymeric Microneedle Sensor for Highly Sensitive and Real-Time Monitoring of Glucose in Interstitial Fluids

Chuljin Hwang, Ju Hyeon Kim, Dae Yu Kim
2 citations
ACS Sensors
Advancements in Transdermal Drug Delivery
1.58
article

Structurally Engineered All-Polymeric Microneedle Sensor for Highly Sensitive and Real-Time Monitoring of Glucose in Interstitial Fluids

Chuljin Hwang, Ju Hyeon Kim, Dae Yu Kim
article en
2 citations

Abstract

Diabetes mellitus (DM) is a chronic metabolic disorder characterized by persistent hyperglycemia with multiple clinical manifestations and complications, such as cardiovascular disease, kidney dysfunction, retinal impairment, and peripheral neuropathy. Continuous and minimally invasive glucose monitoring is essential for effective DM management. Microneedles (MNs)-based sensing platforms offer a promising solution; however, conventional polymeric MNs suffer from limited electrochemical sensitivity due to their insufficient electroactive surface area and inefficient loading of catalytic and enzymatic components. Herein, we present a fully polymeric, high-sensitive glucose sensor based on structurally engineered mushroom-shaped MNs. The MNs were fabricated from a biocompatible composite of triethylene glycol dimethacrylate (TEGDMA) and diurethane dimethacrylate (DUDMA) and further functionalized with poly(3,4-ethylenedioxythiophene)/tosylate (PEDOT/Tos) to enhance electron transport capabilities. A capillary-driven dip-coating process led to the deposition of Pt nanoparticles (Pt NPs)/PEDOT:PSS composite ink into the neck region of the MNs, resulting in localized loading of electrocatalytic material and a significant increase in electrochemical activity. Consequently, the mushroom-shaped MNs exhibited a 12.6-fold enhancement in current response to glucose compared to conical MNs, while maintaining a linear dynamic range between 2 and 20 mM. Furthermore, in vivo validation demonstrated real-time glucose tracking with strong agreement to commercial glucometer readings, and Clarke error grid analysis verified clinical accuracy. Collectively, these results underscore the utility of structural engineering in polymeric MNs to achieve reliable, continuous glucose monitoring for next-generation diabetes care.

ACS SensorsVol. 10(9)
Inha University (KR)
Openalex Percentile: Top 15%
Advancements in Transdermal Drug Delivery
1.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.