A Novel Lipid Microbubble Targeting E-Selectin for Ultrasound Molecular Imaging of Acute Kidney Injury in Rats

Acute kidney injury (AKI) is a common clinical syndrome characterized by abnormal renal function and structure. Microcirculatory perfusion disorders and inflammatory responses are critical pathophysiologies of AKI. Recently, ultrasound molecular imaging has been considered a valuable tool for preclinical and clinical diagnostics that can sensitively target histological structures of interest, particularly in evaluating renal microcirculation. The purpose of this study was to explore a lipid microbubble (MB<sub>E-selectin</sub>) that targets E-selectin molecules expressed on the activated endothelium and to perform ultrasound molecular imaging for the kidney in cisplatin-induced AKI in rats. Using freeze-drying methods, three formular nontargeted microbubbles (NMBs-1, NMBs-2, NMBs-3) were prepared, and three corresponding MB<sub>E-selectin</sub> suspensions (MB<sub>E-selectin</sub>-1, MB<sub>E-selectin</sub>-2, MB<sub>E-selectin</sub>-3) were constructed via maleimide-thiol conjugation chemistry. The results revealed that the physicochemical characteristics of three NMBs and MB<sub>E-selectin</sub> suspensions were usable for intravenous injection as ultrasound contrast agents (UCAs), and the anti-E-selectin antibody successfully conjugated to the lipid shell surface of the bubbles in three MB<sub>E-selectin</sub> suspensions, which could bind specifically to E-selectin molecules expressed on human umbilical vein endothelial cells (HUVECs) treated with tumor necrosis factor-alpha (TNF-α). During ultrasound imaging for the kidney in the cisplatin-induced AKI model, the time-to-peak (TTP) and area under the curve (AUC) of the MB<sub>E-selectin</sub>-2 suspension significantly increased, but the wash-in rate (WIR) and wash-out rate (WOR) significantly decreased compared with those of the NMBs-2 suspension or the control group. The normalized differential targeted enhancement (NdTE) of the MB<sub>E-selectin</sub>-2 suspension was significantly greater than that of the NMBs-2 suspension in the model group, as was the residual-to-saturation ratio (RSR) at 8 min. In conclusion, we successfully prepared a novel MB<sub>E-selectin</sub> suspension carrying an anti-E-selectin antibody that can be used for intravenous injection and can enhance ultrasound imaging of the kidney as a UCA, particularly in a cisplatin-induced AKI model. Ultrasound molecular imaging of the MB<sub>E-selectin</sub> suspension may be helpful for evaluating renal microcirculation or injury in AKI diseases.

Authors

Institutions

Publication Details

Journal
Molecular Pharmaceutics
Published
2025-09-10
DOI
https://doi.org/10.1021/acs.molpharmaceut.5c00883
Citations
1
Primary Topic
Acute Kidney Injury Research
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Lipid Microbubble Targeting E-Selectin for Ultrasound Molecular Imaging of Acute Kidney Injury in Rats

Shuting Ren, Wenbao Zhao, Xiaodong Xue, Jiamei Lu et al.
1 citations
Molecular Pharmaceutics
Acute Kidney Injury Research
1.43
article

A Novel Lipid Microbubble Targeting E-Selectin for Ultrasound Molecular Imaging of Acute Kidney Injury in Rats

Shuting Ren, Wenbao Zhao, Xiaodong Xue, Jiamei Lu, Liping Mo, Rongguo Fu, Ruoyan Si, Zeyu Xu, Yujin Zong, Lina Chen, Changan Zhao, Ziyan Jia
article en
1 citations

Abstract

Acute kidney injury (AKI) is a common clinical syndrome characterized by abnormal renal function and structure. Microcirculatory perfusion disorders and inflammatory responses are critical pathophysiologies of AKI. Recently, ultrasound molecular imaging has been considered a valuable tool for preclinical and clinical diagnostics that can sensitively target histological structures of interest, particularly in evaluating renal microcirculation. The purpose of this study was to explore a lipid microbubble (MB<sub>E-selectin</sub>) that targets E-selectin molecules expressed on the activated endothelium and to perform ultrasound molecular imaging for the kidney in cisplatin-induced AKI in rats. Using freeze-drying methods, three formular nontargeted microbubbles (NMBs-1, NMBs-2, NMBs-3) were prepared, and three corresponding MB<sub>E-selectin</sub> suspensions (MB<sub>E-selectin</sub>-1, MB<sub>E-selectin</sub>-2, MB<sub>E-selectin</sub>-3) were constructed via maleimide-thiol conjugation chemistry. The results revealed that the physicochemical characteristics of three NMBs and MB<sub>E-selectin</sub> suspensions were usable for intravenous injection as ultrasound contrast agents (UCAs), and the anti-E-selectin antibody successfully conjugated to the lipid shell surface of the bubbles in three MB<sub>E-selectin</sub> suspensions, which could bind specifically to E-selectin molecules expressed on human umbilical vein endothelial cells (HUVECs) treated with tumor necrosis factor-alpha (TNF-α). During ultrasound imaging for the kidney in the cisplatin-induced AKI model, the time-to-peak (TTP) and area under the curve (AUC) of the MB<sub>E-selectin</sub>-2 suspension significantly increased, but the wash-in rate (WIR) and wash-out rate (WOR) significantly decreased compared with those of the NMBs-2 suspension or the control group. The normalized differential targeted enhancement (NdTE) of the MB<sub>E-selectin</sub>-2 suspension was significantly greater than that of the NMBs-2 suspension in the model group, as was the residual-to-saturation ratio (RSR) at 8 min. In conclusion, we successfully prepared a novel MB<sub>E-selectin</sub> suspension carrying an anti-E-selectin antibody that can be used for intravenous injection and can enhance ultrasound imaging of the kidney as a UCA, particularly in a cisplatin-induced AKI model. Ultrasound molecular imaging of the MB<sub>E-selectin</sub> suspension may be helpful for evaluating renal microcirculation or injury in AKI diseases.

Molecular PharmaceuticsVol. 22(10)
University of California System (US), China International Science and Technology Cooperation (CN), Second Affiliated Hospital of Zhengzhou University (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 16%
Acute Kidney Injury Research
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.