Elucidating the Interplay Between Resin Media, Feed Constituents, and Process Conditions in AAV Affinity Column Fouling With Confocal Microscopy

In this work, confocal microscopy is employed to study the loading and fouling behavior in AAV affinity resins as well as the implications of resin reuse with several commercial chromatographic materials and feed mixtures. Resin samples are obtained from both batch and column experiments, and confocal microscopy is carried out to examine the adsorption profiles in the beads after loading, wash, elution, and CIP steps. A comparison of PSDVB-based POROS CaptureSelect (PCS) AAV resins with agarose-based AVIPure AAV9 resins revealed distinct differences in both AAV transport and resin fouling. While AAVs were able to fully access the entire PCS AAV resin under loading onto virgin resin materials, they were restricted to the surface region of the AVIPure AAV9 resin. High resolution X-ray CT scans indicate that the large pores of the PCS media are likely responsible for this enhanced transport. However, AAV transport into full PCS AAV resin volume was found to only occur during the first AAV loading experiment and was not observed when clarified lysate was employed or upon resin reuse. Further, confocal microscopy indicated that fouling of the PCS AAV affinity resins occurred due to deposition and carryover of AAV and residual impurities upon column re-use, likely due to incomplete elution and ineffective column CIP. Interestingly, this residual binding in the region near the resin surface resulted in limiting solute transport in subsequent cycles, likely due to pore occlusion. In contrast, AAV bound to the AVIPure resin was readily eluted and removed during CIP. This study elucidates the impact of resin characteristics, feed constituents, and process conditions on the lifetime and fouling of AAV affinity columns.

Authors

Institutions

Publication Details

Journal
Biotechnology and Bioengineering
Published
2025-09-10
DOI
https://doi.org/10.1002/bit.70060
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Elucidating the Interplay Between Resin Media, Feed Constituents, and Process Conditions in AAV Affinity Column Fouling With Confocal Microscopy

Sergey Pryshchep, Harshal Soni, Thomas F. Johnson
Biotechnology and Bioengineering
Protein purification and stability
article

Elucidating the Interplay Between Resin Media, Feed Constituents, and Process Conditions in AAV Affinity Column Fouling With Confocal Microscopy

Sergey Pryshchep, Harshal Soni, Thomas F. Johnson
article en

Abstract

In this work, confocal microscopy is employed to study the loading and fouling behavior in AAV affinity resins as well as the implications of resin reuse with several commercial chromatographic materials and feed mixtures. Resin samples are obtained from both batch and column experiments, and confocal microscopy is carried out to examine the adsorption profiles in the beads after loading, wash, elution, and CIP steps. A comparison of PSDVB-based POROS CaptureSelect (PCS) AAV resins with agarose-based AVIPure AAV9 resins revealed distinct differences in both AAV transport and resin fouling. While AAVs were able to fully access the entire PCS AAV resin under loading onto virgin resin materials, they were restricted to the surface region of the AVIPure AAV9 resin. High resolution X-ray CT scans indicate that the large pores of the PCS media are likely responsible for this enhanced transport. However, AAV transport into full PCS AAV resin volume was found to only occur during the first AAV loading experiment and was not observed when clarified lysate was employed or upon resin reuse. Further, confocal microscopy indicated that fouling of the PCS AAV affinity resins occurred due to deposition and carryover of AAV and residual impurities upon column re-use, likely due to incomplete elution and ineffective column CIP. Interestingly, this residual binding in the region near the resin surface resulted in limiting solute transport in subsequent cycles, likely due to pore occlusion. In contrast, AAV bound to the AVIPure resin was readily eluted and removed during CIP. This study elucidates the impact of resin characteristics, feed constituents, and process conditions on the lifetime and fouling of AAV affinity columns.

Biotechnology and BioengineeringVol. 122(12)
Rensselaer Polytechnic Institute (US), Biochemical Society (GB), University College London (GB)
Openalex Percentile: Top 79%
Protein purification and stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.