Elemental analysis of molybdenum ore using charge coupled device (CCD) and intensified charge-coupled device (ICCD) based LIBS systems

Time-resolved data acquisition is crucial for compositional analysis using Laser-Induced Breakdown Spectroscopy (LIBS). It can be managed by adjusting the delay time and gate width of the spectrometer. This study describes the compositional analysis of molybdenum (Mo) ore utilizing charge coupled device (CCD) and intensified charge-coupled device (ICCD) based LIBS systems. LIBS was successfully used for both quantitative and qualitative analysis of molybdenum ore. Spectra were recorded with CCD and ICCD spectrometers. Plasma parameters were estimated from LIBS spectra to diagnose the plasma thoroughly. A performance comparison was conducted among LIBS measurements using ICCD, CCD, and x-ray fluorescence (XRF). The quantitative analysis of molybdenum ore was carried out using calibration-free LIBS. Both major and trace elements were identified in the spectra. Optical emission spectra showed varying element concentrations of Mo, silicon, aluminum, iron, calcium, potassium, tungsten, and sodium. The XRF was used to compare the performance of LIBS techniques. Results from the compositional analysis of molybdenum ore using ICCD, CCD-based LIBS, and XRF showed good agreement. It is demonstrated that CCD can produce nearly the same results as ICCD within acceptable error margins. The CCD-based LIBS system is a cost-effective analytical method with additional benefits for field applications because it does not require a temperature-controlled environment for operation.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-09-01
DOI
https://doi.org/10.1063/5.0277624
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Elemental analysis of molybdenum ore using charge coupled device (CCD) and intensified charge-coupled device (ICCD) based LIBS systems

Haroon Asghar, Rinda Hedwig, Javed Iqbal, Rizwan Ahmed et al.
Review of Scientific Instruments
Laser-induced spectroscopy and plasma
article

Elemental analysis of molybdenum ore using charge coupled device (CCD) and intensified charge-coupled device (ICCD) based LIBS systems

Haroon Asghar, Rinda Hedwig, Javed Iqbal, Rizwan Ahmed, Naeem Ahmad, M A Baig, A. Sammad, Zeshan Adeel Umar
article en

Abstract

Time-resolved data acquisition is crucial for compositional analysis using Laser-Induced Breakdown Spectroscopy (LIBS). It can be managed by adjusting the delay time and gate width of the spectrometer. This study describes the compositional analysis of molybdenum (Mo) ore utilizing charge coupled device (CCD) and intensified charge-coupled device (ICCD) based LIBS systems. LIBS was successfully used for both quantitative and qualitative analysis of molybdenum ore. Spectra were recorded with CCD and ICCD spectrometers. Plasma parameters were estimated from LIBS spectra to diagnose the plasma thoroughly. A performance comparison was conducted among LIBS measurements using ICCD, CCD, and x-ray fluorescence (XRF). The quantitative analysis of molybdenum ore was carried out using calibration-free LIBS. Both major and trace elements were identified in the spectra. Optical emission spectra showed varying element concentrations of Mo, silicon, aluminum, iron, calcium, potassium, tungsten, and sodium. The XRF was used to compare the performance of LIBS techniques. Results from the compositional analysis of molybdenum ore using ICCD, CCD-based LIBS, and XRF showed good agreement. It is demonstrated that CCD can produce nearly the same results as ICCD within acceptable error margins. The CCD-based LIBS system is a cost-effective analytical method with additional benefits for field applications because it does not require a temperature-controlled environment for operation.

Review of Scientific InstrumentsVol. 96(9)
University of Azad Jammu and Kashmir (PK), Binus University (ID), Shanghai Institute of Optics and Fine Mechanics (CN), Abdus Salam Centre for Physics (PK)
Openalex Percentile: Top 73%
Laser-induced spectroscopy and plasma
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.