Effect of diverticulum entrance diameter on sigmoid sinus hemodynamics: a CFD and PIV experimental validation study

Geometric changes in the sigmoid sinus diverticulum (SSD) can alter its hemodynamic - a primary factor contributing to pulsatile tinnitus (PT). However, not all SSD cases lead to clinical PT symptoms. This study aims to investigate the influence of the diameter of the diverticulum (EDD) on the hemodynamics of the sigmoid sinus in PT. We reconstructed CTA images from 26 PT patients. A statistical analysis of EDD, depth, and diverticulum angle, was conducted across these cases. Based on the geometric characteristics obtained, we established seven idealized models with varying EDDs and performed computational fluid dynamics simulations. Mass flow was set at the inlet, and the outlet was assigned zero pressure. We conducted Particle Image Velocimetry experiments verification. The SSD geometric models were 3D-printed using UV-curable resin material. As the EDD decreased from 11 mm to 9.65 mm, wall pressure within the SSD increased. However, further decreases in EDD from 9.65 mm to 8.3 mm resulted in a reduction in wall pressure (case1: 123.597 Pa vs. case2: 121.325 Pa vs. case3: 128.823 Pa vs. case4: 140.814 Pa vs. case5: 124.172 Pa vs. case6: 120.559 Pa vs. case7: 124.138 Pa). The pressure within the diverticulum first increased and then decreased, with the most intense vortex blood flow observed at an EDD of 9.65 mm. The EDD is a key factor influencing hemodynamic changes within the sigmoid sinus. The intermediate EDD induce more significant blood flow disturbances. This study provides theoretical insights for PT diagnosis and diverticulum morphology assessment.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-09-10
DOI
https://doi.org/10.1080/10255842.2025.2558048
Primary Topic
Cerebral Venous Sinus Thrombosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of diverticulum entrance diameter on sigmoid sinus hemodynamics: a CFD and PIV experimental validation study

Bin Gao, Jie Liu, Feng Zhou, Xiang Ding et al.
Computer Methods in Biomechanics & Biomedical Engineering
Cerebral Venous Sinus Thrombosis
article

Effect of diverticulum entrance diameter on sigmoid sinus hemodynamics: a CFD and PIV experimental validation study

Bin Gao, Jie Liu, Feng Zhou, Xiang Ding, Xueran Ma, Hu Zheng, Suqin Huang
article en

Abstract

Geometric changes in the sigmoid sinus diverticulum (SSD) can alter its hemodynamic - a primary factor contributing to pulsatile tinnitus (PT). However, not all SSD cases lead to clinical PT symptoms. This study aims to investigate the influence of the diameter of the diverticulum (EDD) on the hemodynamics of the sigmoid sinus in PT. We reconstructed CTA images from 26 PT patients. A statistical analysis of EDD, depth, and diverticulum angle, was conducted across these cases. Based on the geometric characteristics obtained, we established seven idealized models with varying EDDs and performed computational fluid dynamics simulations. Mass flow was set at the inlet, and the outlet was assigned zero pressure. We conducted Particle Image Velocimetry experiments verification. The SSD geometric models were 3D-printed using UV-curable resin material. As the EDD decreased from 11 mm to 9.65 mm, wall pressure within the SSD increased. However, further decreases in EDD from 9.65 mm to 8.3 mm resulted in a reduction in wall pressure (case1: 123.597 Pa vs. case2: 121.325 Pa vs. case3: 128.823 Pa vs. case4: 140.814 Pa vs. case5: 124.172 Pa vs. case6: 120.559 Pa vs. case7: 124.138 Pa). The pressure within the diverticulum first increased and then decreased, with the most intense vortex blood flow observed at an EDD of 9.65 mm. The EDD is a key factor influencing hemodynamic changes within the sigmoid sinus. The intermediate EDD induce more significant blood flow disturbances. This study provides theoretical insights for PT diagnosis and diverticulum morphology assessment.

Computer Methods in Biomechanics & Biomedical Engineering
Beijing University of Technology (CN), National Institute of Metrology (CN)
Openalex Percentile: Top 65%
Cerebral Venous Sinus Thrombosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.