Wearable Stimulator for Upper and Lower Limb Somatotopic Sensory Feedback Restoration

Neuroprostheses capable of providing Somatotopic Sensory Feedback (SSF) enables the restoration of tactile sensations in amputees, thereby enhancing prosthesis embodiment, object manipulation, balance and walking stability. Transcutaneous Electrical Nerve Stimulation (TENS) represents a primary non-invasive technique for eliciting somatotopic sensations. Devices commonly used to evaluate the effectiveness of TENS stimulation are often bulky and main powered. However, current portable TENS devices frequently fall short of key functional requirements, particularly in terms of stimulation parameter ranges that are insufficient to reliably evoke somatotopic sensations in either upper and lower limb applications. Moreover, they typically do not support real-time independent channels programming and wireless communication. This work introduces a compact, wearable stimulator, including its external casing, with a total weight of 64 g and dimensions of 70 ${\boldsymbol{\times}}$ 40 ${\boldsymbol{\times}}$ 35 mm, designed to deliver SSF in both upper and lower limb applications. The device was validated through bench testing and human trials involving 20 healthy participants, by comparing the intensity, qualitative characteristics, and referred area of the elicited sensations with those produced by a benchmark. The stimulator reliably delivered the required parameters on a skin-like capacitive-resistive load and elicited somatotopic sensations consistent with the benchmark device and prior somatotopic feedback studies. The proposed stimulator provides non-invasive somatotopic sensory feedback for both upper and lower limbs. Its portability and modular design address key limitations of current commercial and research-grade TENS systems, enabling future studies on the functional benefits of sensory feedback in prosthetic control.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2025-09-09
DOI
https://doi.org/10.1109/tbcas.2025.3607203
Citations
2
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable Stimulator for Upper and Lower Limb Somatotopic Sensory Feedback Restoration

Massimo Barbaro, Riccardo Collu, Loredana Zollo, R. Paolini et al.
2 citations
IEEE Transactions on Biomedical Circuits and Systems
Muscle activation and electromyography studies
1.35
article

Wearable Stimulator for Upper and Lower Limb Somatotopic Sensory Feedback Restoration

Massimo Barbaro, Riccardo Collu, Loredana Zollo, R. Paolini, Andrea Demofonti, Alessia Scarpelli, Francesca Cordella, Laura Tullio
article en
2 citations

Abstract

Neuroprostheses capable of providing Somatotopic Sensory Feedback (SSF) enables the restoration of tactile sensations in amputees, thereby enhancing prosthesis embodiment, object manipulation, balance and walking stability. Transcutaneous Electrical Nerve Stimulation (TENS) represents a primary non-invasive technique for eliciting somatotopic sensations. Devices commonly used to evaluate the effectiveness of TENS stimulation are often bulky and main powered. However, current portable TENS devices frequently fall short of key functional requirements, particularly in terms of stimulation parameter ranges that are insufficient to reliably evoke somatotopic sensations in either upper and lower limb applications. Moreover, they typically do not support real-time independent channels programming and wireless communication. This work introduces a compact, wearable stimulator, including its external casing, with a total weight of 64 g and dimensions of 70 ${\boldsymbol{\times}}$ 40 ${\boldsymbol{\times}}$ 35 mm, designed to deliver SSF in both upper and lower limb applications. The device was validated through bench testing and human trials involving 20 healthy participants, by comparing the intensity, qualitative characteristics, and referred area of the elicited sensations with those produced by a benchmark. The stimulator reliably delivered the required parameters on a skin-like capacitive-resistive load and elicited somatotopic sensations consistent with the benchmark device and prior somatotopic feedback studies. The proposed stimulator provides non-invasive somatotopic sensory feedback for both upper and lower limbs. Its portability and modular design address key limitations of current commercial and research-grade TENS systems, enabling future studies on the functional benefits of sensory feedback in prosthetic control.

IEEE Transactions on Biomedical Circuits and SystemsVol. 20(1)
Università Campus Bio-Medico (IT), University of Cagliari (IT)
Openalex Percentile: Top 18%
Muscle activation and electromyography studies
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.