A soft micron accuracy robot design and clinical validation for retinal surgery

Retinal surgery is one of the most delicate and complex operations, which is close to or even beyond the physiological limitation of the human hand. Robots have demonstrated the ability to filter hand tremors and motion scaling which has a promising output in microsurgery. Here, we present a novel soft micron accuracy robot (SMAR) for retinal surgery and achieve a more precise and safer operation. A remote center of motion (RCM) parallelogram structure with a double spring adaptive balancing mechanism is designed and optimized to achieve precise motion and safer operation. The deviation from the expected trajectory with manual operation and robot-assisted operation is 143.06 μm ± 91.27 μm vs 26.39 μm ± 13.22 μm, which has been significantly improved}. We evaluated the safety performance of SMAR in live animals. Furthermore, preliminary human clinical trials showed that the robot-assisted has less drift compared to the manual operation with 41.07 μm ± 20.78 μm vs 299.66 μm ± 85.84 μm. The visual acuity with LogMAR of cases showed higher improvement in the robot-assisted group preliminary, which for manual of 0.78 ± 0.44 vs robot-assisted 1.24 ± 0.70 with no statistically significant difference. This study provides promising options for robot-assisted with very experienced surgeons in the most challenging microsurgery. The system has the potential to effectively reduce the training curve of doctors and alleviate the shortage of ophthalmic surgeons, which is very important for rural areas and underdeveloped countries.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2025-09-09
DOI
https://doi.org/10.1038/s41378-025-01002-5
Citations
2
Primary Topic
Micro and Nano Robotics
Type
article
Field-Weighted Citation Impact
2.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A soft micron accuracy robot design and clinical validation for retinal surgery

Jiafeng Yu, Tong Min Jiang, Yiqi Chen, Lijun Shen et al.
2 citations
Microsystems & Nanoengineering
Micro and Nano Robotics
2.52
article

A soft micron accuracy robot design and clinical validation for retinal surgery

Jiafeng Yu, Tong Min Jiang, Yiqi Chen, Lijun Shen, Gi‐Hun Yang, Mingchuan Zhou, Alois Knoll, Xiangyu Guo, Xin Ye, Huan Chen, Di Cui
article en
2 citations

Abstract

Retinal surgery is one of the most delicate and complex operations, which is close to or even beyond the physiological limitation of the human hand. Robots have demonstrated the ability to filter hand tremors and motion scaling which has a promising output in microsurgery. Here, we present a novel soft micron accuracy robot (SMAR) for retinal surgery and achieve a more precise and safer operation. A remote center of motion (RCM) parallelogram structure with a double spring adaptive balancing mechanism is designed and optimized to achieve precise motion and safer operation. The deviation from the expected trajectory with manual operation and robot-assisted operation is 143.06 μm ± 91.27 μm vs 26.39 μm ± 13.22 μm, which has been significantly improved}. We evaluated the safety performance of SMAR in live animals. Furthermore, preliminary human clinical trials showed that the robot-assisted has less drift compared to the manual operation with 41.07 μm ± 20.78 μm vs 299.66 μm ± 85.84 μm. The visual acuity with LogMAR of cases showed higher improvement in the robot-assisted group preliminary, which for manual of 0.78 ± 0.44 vs robot-assisted 1.24 ± 0.70 with no statistically significant difference. This study provides promising options for robot-assisted with very experienced surgeons in the most challenging microsurgery. The system has the potential to effectively reduce the training curve of doctors and alleviate the shortage of ophthalmic surgeons, which is very important for rural areas and underdeveloped countries.

Microsystems & NanoengineeringVol. 11(1)
Light Industry Hangzhou Electromechanical Design Institute (CN), Hangzhou Medical College (CN), Technical University of Munich (DE), Zhejiang University (CN)
National Science Foundation, National Natural Science Foundation of China
Openalex Percentile: Top 10%
Micro and Nano Robotics
2.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.