Quantitative and Color‐Coded Assessment of Crown Preparation Using a 3D‐Printed Channel and Hole Guide: A Pilot Comparison With Conventional Guides
The novel channel-type guide showed potential for improving preparation accuracy. However, underprepared areas in critical regions could compromise restoration durability. While the guides had minimal impact on procedure time, further studies are needed to confirm these findings in a wider clinical context.
Authors
- Hyeonjong Lee (ORCID: https://orcid.org/0000-0002-1669-2975)
- Yuwon Jeong (ORCID: https://orcid.org/0000-0002-5258-7291)
- S. W. Ham (ORCID: https://orcid.org/0000-0003-4828-5597)
- Jae Hoon Lee (ORCID: https://orcid.org/0000-0001-6658-4449)
- Jong Cheol Park (ORCID: https://orcid.org/0000-0002-8859-5111)
- Rashdan Muteb J. Alharbi
Institutions
- Yonsei University Dental Hospital (KR)
- Dankook University (KR)
Publication Details
- Journal
- Journal of Dental Education
- Published
- 2025-09-08
- DOI
- https://doi.org/10.1002/jdd.70043
- Primary Topic
- Manufacturing Process and Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Yonsei University
- Yonsei University College of Dentistry