Multi-objective optimization of auxetic coronary stents based on finite element simulation and surrogate modeling

High cost of clinical trials hinders further enhancement of comprehensive mechanical properties of bioresorbable scaffolds (BRS). Therefore, a multi-objective optimization method combining surrogate modeling and finite element simulation is proposed, based on the evaluation of stents with various auxetic structures and materials. The results demonstrated that re-entrant hexagon stent made of PLA (PLA-RH stent) was a more ideal candidate, with superior radial recoil and force. Following optimization, PLA-RH stent decreased bending stiffness by 60.12%, without compromising radial performances. This method enables more precise and efficient optimization and the proposed auxetic structure introduces innovative concepts for future design of stents.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-09-09
DOI
https://doi.org/10.1080/10255842.2025.2556003
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-objective optimization of auxetic coronary stents based on finite element simulation and surrogate modeling

Kuangrong Hao, Yipin Wan, Xiaoyan Liu, Yicun Hua
Computer Methods in Biomechanics & Biomedical Engineering
Coronary Interventions and Diagnostics
article

Multi-objective optimization of auxetic coronary stents based on finite element simulation and surrogate modeling

Kuangrong Hao, Yipin Wan, Xiaoyan Liu, Yicun Hua
article en

Abstract

High cost of clinical trials hinders further enhancement of comprehensive mechanical properties of bioresorbable scaffolds (BRS). Therefore, a multi-objective optimization method combining surrogate modeling and finite element simulation is proposed, based on the evaluation of stents with various auxetic structures and materials. The results demonstrated that re-entrant hexagon stent made of PLA (PLA-RH stent) was a more ideal candidate, with superior radial recoil and force. Following optimization, PLA-RH stent decreased bending stiffness by 60.12%, without compromising radial performances. This method enables more precise and efficient optimization and the proposed auxetic structure introduces innovative concepts for future design of stents.

Computer Methods in Biomechanics & Biomedical Engineering
Donghua University (CN)
Openalex Percentile: Top 61%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.