Facile Deep Brain Electrode Coating with MXene for Improved Electrode Performance

Accurate brain signal recording and precise electrode placement are critical for the success of neuromodulation therapies such as deep brain stimulation (DBS). Addressing these challenges requires deep brain electrodes that provide high-quality, stable recordings while remaining compatible with high-resolution medical imaging modalities like magnetic resonance imaging (MRI). Moreover, such electrodes shall be cost-effective, easy to manufacture, and patient-compatible. In this study, a facile dip-coating approach is proposed using conductive titanium carbide (Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>) MXene nanosheets to enhance the performance of commercially available carbon fiber electrodes for chronic neural recording. Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>-coated electrodes exhibit improved electrical conductivity, environmental and mechanical stabilities, reduced and stable impedance, and enhanced charge storage and injection capacity compared to uncoated carbon electrodes. When implanted in the rat dorsal hippocampal CA1 region, Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes exhibited significantly lower impedance over 4 weeks, reduced susceptibility to 60 Hz line noise, and the capability to detect single-unit neuronal activity-features not observed in uncoated controls. Notably, the Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> coating does not induce inflammation at the implantation sites, and remained fully MRI-compatible, unlike tungsten electrodes. These findings offer a straightforward and practical solution for achieving high-quality chronic deep brain electrophysiology recordings while maintaining biocompatibility, safety, cost-effectiveness, and MRI compatibility.

Authors

Institutions

Publication Details

Journal
Advanced Healthcare Materials
Published
2025-09-09
DOI
https://doi.org/10.1002/adhm.202501169
Citations
1
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.91

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Facile Deep Brain Electrode Coating with MXene for Improved Electrode Performance

Luka Milosevic, Suneil K. Kalia, Taufik A. Valiante, Lorraine V. Kalia et al.
1 citations
Advanced Healthcare Materials
Neuroscience and Neural Engineering
0.91
article

Facile Deep Brain Electrode Coating with MXene for Improved Electrode Performance

Luka Milosevic, Suneil K. Kalia, Taufik A. Valiante, Lorraine V. Kalia, Laura Kondrataviciute, Dong Wook Kim
article en
1 citations

Abstract

Accurate brain signal recording and precise electrode placement are critical for the success of neuromodulation therapies such as deep brain stimulation (DBS). Addressing these challenges requires deep brain electrodes that provide high-quality, stable recordings while remaining compatible with high-resolution medical imaging modalities like magnetic resonance imaging (MRI). Moreover, such electrodes shall be cost-effective, easy to manufacture, and patient-compatible. In this study, a facile dip-coating approach is proposed using conductive titanium carbide (Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>) MXene nanosheets to enhance the performance of commercially available carbon fiber electrodes for chronic neural recording. Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>-coated electrodes exhibit improved electrical conductivity, environmental and mechanical stabilities, reduced and stable impedance, and enhanced charge storage and injection capacity compared to uncoated carbon electrodes. When implanted in the rat dorsal hippocampal CA1 region, Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> electrodes exhibited significantly lower impedance over 4 weeks, reduced susceptibility to 60 Hz line noise, and the capability to detect single-unit neuronal activity-features not observed in uncoated controls. Notably, the Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> coating does not induce inflammation at the implantation sites, and remained fully MRI-compatible, unlike tungsten electrodes. These findings offer a straightforward and practical solution for achieving high-quality chronic deep brain electrophysiology recordings while maintaining biocompatibility, safety, cost-effectiveness, and MRI compatibility.

Advanced Healthcare MaterialsVol. 15(2)
Tufts University (US), University Health Network (CA), University of Toronto (CA), Toronto Western Hospital (CA), Toronto Rehabilitation Institute (CA), Occupational Cancer Research Centre (CA), Max Planck Institute for Intelligent Systems (DE), Krembil Research Institute
National Research Foundation, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 23%
Neuroscience and Neural Engineering
0.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.