Effect of Respiratory Protection Devices on Speech Intelligibility Among Healthcare Workers in a Controlled Environment Simulating the Clinical Setting

Modified Rhyme Test (MRT) scores were significantly lower when wearing the CleanSpace Halo (-10.22 points, 95% CI [-11.28, -9.20]) and the elastomeric half mask respirator (EHMR) with or without the exhalation valve filter (-2.28 points, 95% CI [-3.33, -1.20] and -3.22 points, 95% CI [-4.40, -2.18] respectively) after adjusting for noise level, listener respiratory PPE, and correlation within each participant.Conclusions/Applications to practice:Elastomeric half mask respirator (EHMR) decreased speech intelligibility compromising clear communications. Further research on respiratory PPE design is needed to optimize speech intelligibility and communication maximally.

Authors

Institutions

Publication Details

Journal
Workplace Health & Safety
Published
2025-09-09
DOI
https://doi.org/10.1177/21650799251361957
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Respiratory Protection Devices on Speech Intelligibility Among Healthcare Workers in a Controlled Environment Simulating the Clinical Setting

Barite Dawud, Sandra Castro‐Pearson, Ruth Bryant, J.M. Smith et al.
Workplace Health & Safety
Infection Control and Ventilation
article

Effect of Respiratory Protection Devices on Speech Intelligibility Among Healthcare Workers in a Controlled Environment Simulating the Clinical Setting

Barite Dawud, Sandra Castro‐Pearson, Ruth Bryant, J.M. Smith, Ned K. Tervola, Catherine A. St. Hill, Siobhán Dugan, Rachel Zerby
article en

Abstract

Modified Rhyme Test (MRT) scores were significantly lower when wearing the CleanSpace Halo (-10.22 points, 95% CI [-11.28, -9.20]) and the elastomeric half mask respirator (EHMR) with or without the exhalation valve filter (-2.28 points, 95% CI [-3.33, -1.20] and -3.22 points, 95% CI [-4.40, -2.18] respectively) after adjusting for noise level, listener respiratory PPE, and correlation within each participant.Conclusions/Applications to practice:Elastomeric half mask respirator (EHMR) decreased speech intelligibility compromising clear communications. Further research on respiratory PPE design is needed to optimize speech intelligibility and communication maximally.

Workplace Health & SafetyVol. 73(12)
Abbott Northwestern Hospital (US), Allina Health (US), Essentia Health (US), Minnesota Department of Labor and Industry (US), Medtronic (Ireland) (IE), Mayo Clinic Health System (US), Mayo Clinic in Arizona (US)
Openalex Percentile: Top 65%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.