A Simple Double-Line-Frequency Pulsating Power Mitigation for Grid-Forming Converters Under Imbalanced Grids

Traditional grid-forming (GFM) converters based on the quasi steady-state power control are sensitive to negative sequence grid voltage disturbances, causing significant double-line-frequency power oscillations. Traditional power oscillation suppression methods are mainly based on complex sequence decomposition, with complex algorithms and large amount of calculation. In this article, a simple pulsating power mitigation approach is proposed for GFM converters, without using any sequence decomposition of converter line current nor grid voltage. The proposed system is implemented by only adding a simple pulsating active power mitigation loop to produce an adjustable factor that multiplies with the instantaneous converter voltage. Based on the adjustable factor, the compensation voltage can be easily extracted and added to the original reference voltage from GFM power controller. With this slight modification, the pulsating active power can be effectively suppressed in various voltage imbalance conditions and power operation points. Extensive analysis and experimental results have been obtained to validate the correctness of the proposed approach.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Electronics
Published
2025-09-08
DOI
https://doi.org/10.1109/tie.2025.3589422
Citations
1
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simple Double-Line-Frequency Pulsating Power Mitigation for Grid-Forming Converters Under Imbalanced Grids

Bingtao Zhang, Lucheng Hong, Jinwei He
1 citations
IEEE Transactions on Industrial Electronics
High-Voltage Power Transmission Systems
0.73
article

A Simple Double-Line-Frequency Pulsating Power Mitigation for Grid-Forming Converters Under Imbalanced Grids

Bingtao Zhang, Lucheng Hong, Jinwei He
article en
1 citations

Abstract

Traditional grid-forming (GFM) converters based on the quasi steady-state power control are sensitive to negative sequence grid voltage disturbances, causing significant double-line-frequency power oscillations. Traditional power oscillation suppression methods are mainly based on complex sequence decomposition, with complex algorithms and large amount of calculation. In this article, a simple pulsating power mitigation approach is proposed for GFM converters, without using any sequence decomposition of converter line current nor grid voltage. The proposed system is implemented by only adding a simple pulsating active power mitigation loop to produce an adjustable factor that multiplies with the instantaneous converter voltage. Based on the adjustable factor, the compensation voltage can be easily extracted and added to the original reference voltage from GFM power controller. With this slight modification, the pulsating active power can be effectively suppressed in various voltage imbalance conditions and power operation points. Extensive analysis and experimental results have been obtained to validate the correctness of the proposed approach.

IEEE Transactions on Industrial ElectronicsVol. 73(1)
Tianjin University (CN), Tianjin Foreign Studies University (CN), Southeast University (BD), Southeast University (CN)
Openalex Percentile: Top 24%
High-Voltage Power Transmission Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.