Test method for permissible heating of asynchronous electric motors operating in intermittent modes as part of variable frequency drives with pulse-width modulation

Currently, energy saving problems, especially in the agro-industrial sector, is of significant importance and relevance, in this regard, studies of energy modes of frequency-controlled asynchronous AC electric drives with pulse-width modulation (PWM) are of particular practical importance. To a large extent, this concerns the most important for energy saving modes indices of power losses in a frequency-controlled asynchronous machine and its overheating during operation in stationary and cyclic modes widely used in water supply installations in rural areas, conveyors in grain storage facilities, agro-industrial complexes for raising livestock and poultry. The research goal is to eliminate the possibility of overheating of asynchronous electric motors operating in intermittent modes as part of frequency-controlled electric drives with PWM. The essence of checking an asynchronous electric motor for heating is to compare the permissible temperature for the insulation class of its windings with the one it has when performing technological processes. This check is performed by direct or indirect methods of research and calculations. The studies discussed were conducted using mathematical calculations and modeling of electromechanical processes. A necessary condition for the normal operation of a frequency-controlled asynchronous machine without thermal overheating in continuous modes is not exceeding the actually created total electromagnetic power of losses and thus, by the power losses, equivalent current, torque, one can indirectly judge the overheating of the motor. The formulas of dependencies derived in the study may be used for engineering calculations to check the permissible thermal heating and control the energy consumption of self-ventilated asynchronous electric motors fed from static converters with PWM and operating in variable repetitive modes including at livestock and poultry enterprises.

Publication Details

Journal
Vestnik Altajskogo gosudarstvennogo agrarnogo universiteta
Published
2025-07-11
DOI
https://doi.org/10.53083/1996-4277-2025-249-7-79-86
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test method for permissible heating of asynchronous electric motors operating in intermittent modes as part of variable frequency drives with pulse-width modulation

Vestnik Altajskogo gosudarstvennogo agrarnogo universiteta
Electric Power Systems and Control
article

Test method for permissible heating of asynchronous electric motors operating in intermittent modes as part of variable frequency drives with pulse-width modulation

article en

Abstract

Currently, energy saving problems, especially in the agro-industrial sector, is of significant importance and relevance, in this regard, studies of energy modes of frequency-controlled asynchronous AC electric drives with pulse-width modulation (PWM) are of particular practical importance. To a large extent, this concerns the most important for energy saving modes indices of power losses in a frequency-controlled asynchronous machine and its overheating during operation in stationary and cyclic modes widely used in water supply installations in rural areas, conveyors in grain storage facilities, agro-industrial complexes for raising livestock and poultry. The research goal is to eliminate the possibility of overheating of asynchronous electric motors operating in intermittent modes as part of frequency-controlled electric drives with PWM. The essence of checking an asynchronous electric motor for heating is to compare the permissible temperature for the insulation class of its windings with the one it has when performing technological processes. This check is performed by direct or indirect methods of research and calculations. The studies discussed were conducted using mathematical calculations and modeling of electromechanical processes. A necessary condition for the normal operation of a frequency-controlled asynchronous machine without thermal overheating in continuous modes is not exceeding the actually created total electromagnetic power of losses and thus, by the power losses, equivalent current, torque, one can indirectly judge the overheating of the motor. The formulas of dependencies derived in the study may be used for engineering calculations to check the permissible thermal heating and control the energy consumption of self-ventilated asynchronous electric motors fed from static converters with PWM and operating in variable repetitive modes including at livestock and poultry enterprises.

Vestnik Altajskogo gosudarstvennogo agrarnogo universitetaVol. 249(7)
Openalex Percentile: Top 77%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Test method for permissible heating of asynchronous electric motors operating in intermittent modes as part of variable frequency drives with pulse-width modulation · Vestnik Altajskogo gosudarstvennogo agrarnogo universiteta (2025) | TGRS Research Map | TGRS