Analysis of Unsharp Mask Technique Application on Clinical Stroke MRI Brain Examination using Arterial Spin Labeling (ASL) Sequence in Image Information

Magnetic Resonance Imaging (MRI) with Arterial Spin Labeling (ASL) is a non-invasive technique commonly used to assess cerebral perfusion, especially in stroke patients. However, ASL images often suffer from low contrast and high noise, which can hinder diagnostic accuracy in visualizing perfusion areas and detecting ischemic lesions. Image enhancement techniques, such as the unsharp mask, offer a potential solution to improve image quality. The effectiveness of this enhancement depends on the kernel size used in the unsharp mask filter. This study evaluates the impact of different kernel sizes (3×3, 5×5, and 7×7) on the quality of ASL brain images, focusing on both quantitative and qualitative improvements. A total of 63 ASL brain MRI images from stroke patients were processed using unsharp mask filters with the three kernel sizes. Quantitative analysis measured Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR), while qualitative assessment involved three radiologists independently evaluating five aspects of image quality: perfusion area clarity, grey-white matter contrast, ischemic lesion boundary visibility, noise level, and overall visual quality. Statistical tests, including Friedman and Wilcoxon, were applied to compare results across the kernel sizes. Results revealed that the 3×3 kernel achieved the best results in both quantitative and qualitative assessments, with the highest SNR, CNR, and visual quality scores. Significant differences (p < 0.05) were found between kernel sizes, confirming the superiority of the 3×3 kernel. The 7×7 kernel reduced noise but caused oversmoothing, negatively impacting image sharpness. In conclusion, the 3×3 kernel provides an optimal balance between noise reduction and edge preservation, enhancing ASL brain image quality for stroke diagnosis.

Authors

Institutions

Publication Details

Journal
International Journal of Health and Social Behavior
Published
2025-08-30
DOI
https://doi.org/10.62951/ijhsb.v2i3.507
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Unsharp Mask Technique Application on Clinical Stroke MRI Brain Examination using Arterial Spin Labeling (ASL) Sequence in Image Information

Sugiyanto Sugiyanto, Gatot Murti Wibowo, Tri Asih Budiati, Esensia Azama Bioasa
1 links
International Journal of Health and Social Behavior
Advanced MRI Techniques and Applications
article

Analysis of Unsharp Mask Technique Application on Clinical Stroke MRI Brain Examination using Arterial Spin Labeling (ASL) Sequence in Image Information

Sugiyanto Sugiyanto, Gatot Murti Wibowo, Tri Asih Budiati, Esensia Azama Bioasa
article en

Abstract

Magnetic Resonance Imaging (MRI) with Arterial Spin Labeling (ASL) is a non-invasive technique commonly used to assess cerebral perfusion, especially in stroke patients. However, ASL images often suffer from low contrast and high noise, which can hinder diagnostic accuracy in visualizing perfusion areas and detecting ischemic lesions. Image enhancement techniques, such as the unsharp mask, offer a potential solution to improve image quality. The effectiveness of this enhancement depends on the kernel size used in the unsharp mask filter. This study evaluates the impact of different kernel sizes (3×3, 5×5, and 7×7) on the quality of ASL brain images, focusing on both quantitative and qualitative improvements. A total of 63 ASL brain MRI images from stroke patients were processed using unsharp mask filters with the three kernel sizes. Quantitative analysis measured Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR), while qualitative assessment involved three radiologists independently evaluating five aspects of image quality: perfusion area clarity, grey-white matter contrast, ischemic lesion boundary visibility, noise level, and overall visual quality. Statistical tests, including Friedman and Wilcoxon, were applied to compare results across the kernel sizes. Results revealed that the 3×3 kernel achieved the best results in both quantitative and qualitative assessments, with the highest SNR, CNR, and visual quality scores. Significant differences (p < 0.05) were found between kernel sizes, confirming the superiority of the 3×3 kernel. The 7×7 kernel reduced noise but caused oversmoothing, negatively impacting image sharpness. In conclusion, the 3×3 kernel provides an optimal balance between noise reduction and edge preservation, enhancing ASL brain image quality for stroke diagnosis.

International Journal of Health and Social BehaviorVol. 2(3)
Politeknik Kesehatan Kemenkes Semarang (ID)
Openalex Percentile: Top 67%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.