Analytical Design of an Automated Microfluidic System and Its Application for the Determination of Nitrite Ions in Environmental Samples

This study describes the development of a fully automated microfluidic spectrophotometric system for detecting various pollutants, including nitrite, in the Shatt al-Arab River in the Basra governorate of southern Iraq.The proposed system offers a simple, effective, and efficient analytical approach characterized by high sample throughput, low reagent consumption, and minimal sample volume requirements.The custom-fabricated microfluidic chip has a total volume capacity of 25 L and a length of 10cm.It consisted of three microchannels, two channels with individual volumes of 10 L, and the third with a volume of 5L.Three Arduino-controlled peristaltic pumps were employed, supported by in-house developed software to control the flow rates of both reagent introduction and sample loading.Data acquisition was performed by recording peak heights corresponding to sample concentrations using the Microsoft Excel 2016 program.Application of the system to real samples from the Shatt Al-Arab River revealed the nitrite concentration ranging from 0.006 to 0.06 g mL -1 .The method demonstrated a detection limit of 110 (- 4) gmL -1 and exhibited excellent precision, with a relative standard deviation (RSD%) of 0.379% for ten replicate measurements at a concentration of 0.1 g/mL.Linearity was established in the range of (0.01-0.1) gmL -1 , yielding a correlation coefficient (R 2 ) of 0.9998 based on ten data points.Each analysis of a sample required only 50l of reagents, resulting in a total reagent consumption of 30 mL for 600 analyses within an hour.Consequently, this system is eco-friendly due to its minimal waste levels.

Authors

Publication Details

Journal
International Journal of Environmental Impacts
Published
2025-08-31
DOI
https://doi.org/10.18280/ijei.080418
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Design of an Automated Microfluidic System and Its Application for the Determination of Nitrite Ions in Environmental Samples

Rana T. Shibli, Kamail H. Al-Sowdani
International Journal of Environmental Impacts
Analytical Chemistry and Sensors
article

Analytical Design of an Automated Microfluidic System and Its Application for the Determination of Nitrite Ions in Environmental Samples

Rana T. Shibli, Kamail H. Al-Sowdani
article en

Abstract

This study describes the development of a fully automated microfluidic spectrophotometric system for detecting various pollutants, including nitrite, in the Shatt al-Arab River in the Basra governorate of southern Iraq.The proposed system offers a simple, effective, and efficient analytical approach characterized by high sample throughput, low reagent consumption, and minimal sample volume requirements.The custom-fabricated microfluidic chip has a total volume capacity of 25 L and a length of 10cm.It consisted of three microchannels, two channels with individual volumes of 10 L, and the third with a volume of 5L.Three Arduino-controlled peristaltic pumps were employed, supported by in-house developed software to control the flow rates of both reagent introduction and sample loading.Data acquisition was performed by recording peak heights corresponding to sample concentrations using the Microsoft Excel 2016 program.Application of the system to real samples from the Shatt Al-Arab River revealed the nitrite concentration ranging from 0.006 to 0.06 g mL -1 .The method demonstrated a detection limit of 110 (- 4) gmL -1 and exhibited excellent precision, with a relative standard deviation (RSD%) of 0.379% for ten replicate measurements at a concentration of 0.1 g/mL.Linearity was established in the range of (0.01-0.1) gmL -1 , yielding a correlation coefficient (R 2 ) of 0.9998 based on ten data points.Each analysis of a sample required only 50l of reagents, resulting in a total reagent consumption of 30 mL for 600 analyses within an hour.Consequently, this system is eco-friendly due to its minimal waste levels.

International Journal of Environmental ImpactsVol. 8(4)
Openalex Percentile: Top 68%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.