Research on Electromagnetic Interference of Arc Discharge on X-Ray Detectors

Using X-ray detectors to inspect power lines can promptly identify defects and eliminate potential hazards. However, during operation, X-ray detectors require equal potential at the input/output, which can lead to arc discharge of suspended potential conductors, creating intense electromagnetic changes that severely disrupt the normal operation of the X-ray detector. This paper analyzes the potential impacts of such arc discharge on X-ray detectors and establishes a three-dimensional model. The FDTD and TLM hybrid algorithm is used for simulation analysis of the power density inside the X-ray detector, the induced voltage in the internal and external cables under the influence of the arc discharge field, and electromagnetic compatibility assessment. Finally, the induced current in the external cables is measured, with the simulation results matching the measured results well. When X-ray detectors are applied in power line environments, the internal high-speed circuits, embedded computers, and CCDs need to be reinforced with electromagnetic protection. The induced voltage on the RJ45 connecting the inside and outside of the X-ray detector reaches 21.89V, requiring transient overvoltage suppression at the interface.

Authors

Institutions

Publication Details

Published
2025-04-23
DOI
https://doi.org/10.1109/acctcs66275.2025.00053
Primary Topic
Welding Techniques and Residual Stresses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Electromagnetic Interference of Arc Discharge on X-Ray Detectors

Xingfa Liu, Guangkai Yu, Jinbin Li, Zheyuan Gan
Welding Techniques and Residual Stresses
article

Research on Electromagnetic Interference of Arc Discharge on X-Ray Detectors

Xingfa Liu, Guangkai Yu, Jinbin Li, Zheyuan Gan
article en

Abstract

Using X-ray detectors to inspect power lines can promptly identify defects and eliminate potential hazards. However, during operation, X-ray detectors require equal potential at the input/output, which can lead to arc discharge of suspended potential conductors, creating intense electromagnetic changes that severely disrupt the normal operation of the X-ray detector. This paper analyzes the potential impacts of such arc discharge on X-ray detectors and establishes a three-dimensional model. The FDTD and TLM hybrid algorithm is used for simulation analysis of the power density inside the X-ray detector, the induced voltage in the internal and external cables under the influence of the arc discharge field, and electromagnetic compatibility assessment. Finally, the induced current in the external cables is measured, with the simulation results matching the measured results well. When X-ray detectors are applied in power line environments, the internal high-speed circuits, embedded computers, and CCDs need to be reinforced with electromagnetic protection. The induced voltage on the RJ45 connecting the inside and outside of the X-ray detector reaches 21.89V, requiring transient overvoltage suppression at the interface.

China Electric Power Research Institute
Openalex Percentile: Top 76%
Welding Techniques and Residual Stresses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.