Security Driven Product Design for Open-Source Medical Syringe Infusion Pumps

Open-source medical devices, including syringe infusion pumps, have gained popularity due to their cost-effectiveness and adaptability. However, integrating open-source components, such as their open-source software controlling system, raises significant cybersecurity concerns. This paper investigates cybersecurity vulnerability targeting an open-source medical syringe pump. We present a DDoS attack that alters the pump's operation, potentially leading to over-infusion or under-infusion of medication. We then assess the implications of these security flaws on patient safety and device reliability. Based on this assessment, we propose mitigation strategies that involve hardware modifications to enhance the device's resistance to such attacks and change designs for the 3D printing hardware pieces for open electronics. This research highlights the urgent need for security-driven product design, where security considerations guide the healthcare product's design choices and implementation.

Authors

Institutions

Publication Details

Published
2025-03-15
DOI
https://doi.org/10.1109/isec64801.2025.11147320
Primary Topic
Security and Verification in Computing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Security Driven Product Design for Open-Source Medical Syringe Infusion Pumps

Lisa Hix, C. W. Mead, Wei Lu, James E. Fitzpatrick et al.
Security and Verification in Computing
article

Security Driven Product Design for Open-Source Medical Syringe Infusion Pumps

Lisa Hix, C. W. Mead, Wei Lu, James E. Fitzpatrick, Elvin Colon
article en

Abstract

Open-source medical devices, including syringe infusion pumps, have gained popularity due to their cost-effectiveness and adaptability. However, integrating open-source components, such as their open-source software controlling system, raises significant cybersecurity concerns. This paper investigates cybersecurity vulnerability targeting an open-source medical syringe pump. We present a DDoS attack that alters the pump's operation, potentially leading to over-infusion or under-infusion of medication. We then assess the implications of these security flaws on patient safety and device reliability. Based on this assessment, we propose mitigation strategies that involve hardware modifications to enhance the device's resistance to such attacks and change designs for the 3D printing hardware pieces for open electronics. This research highlights the urgent need for security-driven product design, where security considerations guide the healthcare product's design choices and implementation.

Vol. 2025
Keene State College (US)
Openalex Percentile: Top 88%
Security and Verification in Computing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.