Esophageal Hematoma Following Transcatheter Edge-to-Edge Repair of the Mitral Valve: A Rare Complication of Transesophageal Echocardiography

Transesophageal echocardiography is commonly used to guide structural cardiac interventions but carries a risk of esophageal injury. We present a 79-year-old woman who underwent a Transcatheter Edge-to-Edge Repair of the mitral valve and developed an esophageal hematoma. Clinical course was complicated by intractable gastrointestinal bleeding and sepsis due to acute cholecystitis. She did not survive despite aggressive measures. Our case demonstrates the potential severity of transesophageal echocardiography-related complications, especially in patients with predisposing factors such as esophageal diverticula and anticoagulation use.

Authors

Institutions

Publication Details

Journal
ACG Case Reports Journal
Published
2025-09-01
DOI
https://doi.org/10.14309/crj.0000000000001822
Primary Topic
Cardiac Structural Anomalies and Repair
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Esophageal Hematoma Following Transcatheter Edge-to-Edge Repair of the Mitral Valve: A Rare Complication of Transesophageal Echocardiography

Nishant Aggarwal, Mohammed Alkhero, Ahmed Aref, Ketan Rana et al.
2 links
ACG Case Reports Journal
Cardiac Structural Anomalies and Repair
article

Esophageal Hematoma Following Transcatheter Edge-to-Edge Repair of the Mitral Valve: A Rare Complication of Transesophageal Echocardiography

Nishant Aggarwal, Mohammed Alkhero, Ahmed Aref, Ketan Rana, Mohammad Ali Sheffeh, Fady Banno, Judy Sheffeh
article en

Abstract

Transesophageal echocardiography is commonly used to guide structural cardiac interventions but carries a risk of esophageal injury. We present a 79-year-old woman who underwent a Transcatheter Edge-to-Edge Repair of the mitral valve and developed an esophageal hematoma. Clinical course was complicated by intractable gastrointestinal bleeding and sepsis due to acute cholecystitis. She did not survive despite aggressive measures. Our case demonstrates the potential severity of transesophageal echocardiography-related complications, especially in patients with predisposing factors such as esophageal diverticula and anticoagulation use.

ACG Case Reports JournalVol. 12(9)
Michigan Surgical Hospital (US), Beaumont Hospital, Royal Oak (US)
Openalex Percentile: Top 62%
Cardiac Structural Anomalies and Repair
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Esophageal Hematoma Following Transcatheter Edge-to-Edge Repair of the Mitral Valve: A Rare Complication of Transesophageal Echocardiography — Nishant Aggarwal, Mohammed Alkhero, et al. · ACG Case Reports Journal (2025) | TGRS Research Map | TGRS