Analytical method development and validation for brivaracetam in oral liquid dosage form by UPHPLC method

A new method was established for estimation of Brivaracetam by UHPLC method. The chromatographic conditions were successfully developed for the Brivaracetam by using C18 column (3mm×50mm with 3 microns), flow rate was 0.3ml/min, mobile phase ratio was (80:10:10v/v) Acetonitrile: Buffer (phosphate buffer) pH 3.0 to 4.5 (adjusted with orthophosphoric acid), detection wavelength was 215nm. The instrument used was AGLIENT UHPLC model: 1220 infinity, software – open lab – chemstation. In compliance with ICH criteria, the analytical procedure was verified (ICH, Q2). According to the linearity investigation, the concentration range of brivaracetam was 4.94 mcg/ml to 14.81 mcg/ml, and the correlation coefficient (R2) was 0.9999. The precision study was repeatable, reliable, and accurate.

Authors

Institutions

Publication Details

Journal
Future Journal of Pharmaceuticals and Health Sciences
Published
2025-08-20
DOI
https://doi.org/10.26452/fjphs.v5i3.804
Primary Topic
Epilepsy research and treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical method development and validation for brivaracetam in oral liquid dosage form by UPHPLC method

Kakkudiyil I. Abraham, P.S. Monika, Sama Ajay, Munialo C Stewart K et al.
Future Journal of Pharmaceuticals and Health Sciences
Epilepsy research and treatment
article

Analytical method development and validation for brivaracetam in oral liquid dosage form by UPHPLC method

Kakkudiyil I. Abraham, P.S. Monika, Sama Ajay, Munialo C Stewart K, J. Christopher, S Sanjiv.
article en

Abstract

A new method was established for estimation of Brivaracetam by UHPLC method. The chromatographic conditions were successfully developed for the Brivaracetam by using C18 column (3mm×50mm with 3 microns), flow rate was 0.3ml/min, mobile phase ratio was (80:10:10v/v) Acetonitrile: Buffer (phosphate buffer) pH 3.0 to 4.5 (adjusted with orthophosphoric acid), detection wavelength was 215nm. The instrument used was AGLIENT UHPLC model: 1220 infinity, software – open lab – chemstation. In compliance with ICH criteria, the analytical procedure was verified (ICH, Q2). According to the linearity investigation, the concentration range of brivaracetam was 4.94 mcg/ml to 14.81 mcg/ml, and the correlation coefficient (R2) was 0.9999. The precision study was repeatable, reliable, and accurate.

Future Journal of Pharmaceuticals and Health SciencesVol. 5(3)
Sri Chandrasekharendra Saraswathi Viswa Mahavidyalaya (IN), Third Way (US), ASA College (US), Sri Balaji Vidyapeeth University (IN), Hindu College of Pharmacy (IN)
Openalex Percentile: Top 72%
Epilepsy research and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.