A126 Development and evaluation of a low-cost, high fidelity, reusable, focussed assessment with sonography in trauma (FAST) simulator

Introduction: Focused assessment sonography in trauma (FAST) is an important adjunct to doctors in emergency medicine and surgical settings for patients with blunt trauma by identifying intraperitoneal and pericardial free fluid through 4 basic views [1]. The practical training in FAST currently uses either clinical patients or simulation models (phantoms) [2]. However, these phantoms are often expensive, low fidelity, and/or have fixed anatomy [2]. This project aims to manufacture and evaluate a low-cost, high-fidelity, reusable, and dynamic FAST phantom focusing on abdominal views. Methods: To construct the phantom, food storage containers were placed into a plastic torso. Aqueous dietary fibre antifreeze mix (ADAMgel) was used to make the Liver and Spleen [3]. Kidneys were made using ADAMgel as a proxy medulla and gelatine for the cortex. The dynamic elements of the model were assembled using a balloon and medical tubing system, attached to a 3-way tap, syringe, and saline. The elements were placed in the respective containers in the torso. The FAST phantom was evaluated by acute speciality doctors, who completed a pre-and post-intervention questionnaire collecting data via a 5-point Likert scale. The questions were based on the acquisition of knowledge and skills. Additional questions in the post-intervention questionnaire tested the phantom’s realism. The Likert data from the questionnaire was analysed using descriptive statistics, as shown in Table 1-A126. Data analysis of Likert data from participant questionnaires. Left upper quadrant (LUQ), Right upper quadrant (RUQ) Results: The FAST phantom was tested by 10 acute-specialty doctors. Its sonographic realism was rated highly with at least 70% of responses agree or strongly agree. In the questions assessed pre-and post-intervention, at least one quartile increased post-intervention and 100% of the upper quartiles were Likert 5 (strongly agree), suggesting it was a valuable educational tool. Discussion: The FAST phantom improved doctors’ knowledge, skills and confidence regarding FAST, with good sonographic anatomical realism and dynamic images. This was a small-scale, proof-of-concept project, requiring further development, testing and validation. The promising results suggest this low-cost, high-fidelity, reusable, and dynamic FAST phantom could allow greater access to simulated FAST training through more economically and environmentally sustainable routes. Ethics statement: Authors confirm that all relevant ethical standards for research conduct and dissemination have been met. The submitting author confirms that relevant ethical approval was granted, if applicable References 1. Richards JR, McGahan JP. Focused Assessment with Sonography in Trauma (FAST) in 2017: What Radiologists Can Learn. Radiology. 2017;283(1):30–48. 2. Al-Zogbi L, Bock B, Schaffer S, Fleiter T, Krieger A. A 3-D-Printed Patient-Specific Ultrasound Phantom for FAST Scan. Ultrasound Medical Biologoy. 2021;47(3):820–832. 3. Willers J, Colucci G, Roberts A, Barnes L. 0031 Adamgel: An economical, easily prepared, versatile, selfrepairing and recyclable tissue analogue for procedural simulation training. BMJ Simulation & Technology Enhanced Learning. 2015;1(suppl 2):A27. Acknowledgments: All funding for this project originates from Brighton and Sussex Medical School.

Authors

Publication Details

Journal
Journal of Healthcare Simulation
Published
2024-11-04
DOI
https://doi.org/10.54531/bzvo8427
Primary Topic
Trauma and Emergency Care Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A126 Development and evaluation of a low-cost, high fidelity, reusable, focussed assessment with sonography in trauma (FAST) simulator

Johann Willers, Frederick Stourton, Gianluca Colucci, Samuel Martin et al.
Journal of Healthcare Simulation
Trauma and Emergency Care Studies
article

A126 Development and evaluation of a low-cost, high fidelity, reusable, focussed assessment with sonography in trauma (FAST) simulator

Johann Willers, Frederick Stourton, Gianluca Colucci, Samuel Martin, Amy Sanders, Shatha Shahin Shahin
article en

Abstract

Introduction: Focused assessment sonography in trauma (FAST) is an important adjunct to doctors in emergency medicine and surgical settings for patients with blunt trauma by identifying intraperitoneal and pericardial free fluid through 4 basic views [1]. The practical training in FAST currently uses either clinical patients or simulation models (phantoms) [2]. However, these phantoms are often expensive, low fidelity, and/or have fixed anatomy [2]. This project aims to manufacture and evaluate a low-cost, high-fidelity, reusable, and dynamic FAST phantom focusing on abdominal views. Methods: To construct the phantom, food storage containers were placed into a plastic torso. Aqueous dietary fibre antifreeze mix (ADAMgel) was used to make the Liver and Spleen [3]. Kidneys were made using ADAMgel as a proxy medulla and gelatine for the cortex. The dynamic elements of the model were assembled using a balloon and medical tubing system, attached to a 3-way tap, syringe, and saline. The elements were placed in the respective containers in the torso. The FAST phantom was evaluated by acute speciality doctors, who completed a pre-and post-intervention questionnaire collecting data via a 5-point Likert scale. The questions were based on the acquisition of knowledge and skills. Additional questions in the post-intervention questionnaire tested the phantom’s realism. The Likert data from the questionnaire was analysed using descriptive statistics, as shown in Table 1-A126. Data analysis of Likert data from participant questionnaires. Left upper quadrant (LUQ), Right upper quadrant (RUQ) Results: The FAST phantom was tested by 10 acute-specialty doctors. Its sonographic realism was rated highly with at least 70% of responses agree or strongly agree. In the questions assessed pre-and post-intervention, at least one quartile increased post-intervention and 100% of the upper quartiles were Likert 5 (strongly agree), suggesting it was a valuable educational tool. Discussion: The FAST phantom improved doctors’ knowledge, skills and confidence regarding FAST, with good sonographic anatomical realism and dynamic images. This was a small-scale, proof-of-concept project, requiring further development, testing and validation. The promising results suggest this low-cost, high-fidelity, reusable, and dynamic FAST phantom could allow greater access to simulated FAST training through more economically and environmentally sustainable routes. Ethics statement: Authors confirm that all relevant ethical standards for research conduct and dissemination have been met. The submitting author confirms that relevant ethical approval was granted, if applicable References 1. Richards JR, McGahan JP. Focused Assessment with Sonography in Trauma (FAST) in 2017: What Radiologists Can Learn. Radiology. 2017;283(1):30–48. 2. Al-Zogbi L, Bock B, Schaffer S, Fleiter T, Krieger A. A 3-D-Printed Patient-Specific Ultrasound Phantom for FAST Scan. Ultrasound Medical Biologoy. 2021;47(3):820–832. 3. Willers J, Colucci G, Roberts A, Barnes L. 0031 Adamgel: An economical, easily prepared, versatile, selfrepairing and recyclable tissue analogue for procedural simulation training. BMJ Simulation & Technology Enhanced Learning. 2015;1(suppl 2):A27. Acknowledgments: All funding for this project originates from Brighton and Sussex Medical School.

Journal of Healthcare Simulation
Openalex Percentile: Top 55%
Trauma and Emergency Care Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.