Impact of Bileaflet Mechanical Heart Valve implantation angle on left ventricular hemodynamics and blood cell damage

<i>Purpose:</i> The implantation angle of Bileaflet Mechanical Heart Valve (BMHV) is critical issue in valve replacement surgery. Investigating the local hemodynamic characteristics and analyzing the postoperative flow dynamics can provide valuable insights for determining the optimal implantation angle, thereby offering clinical guidance for improved surgical outcomes. <i>Methods:</i> Three-dimensional anatomical model of the Left Ventricle (LV) and BMHV was reconstructed based on patient-specific medical imaging data and anatomical parameters. The hemodynamic effects of varying implantation angles were investigated using Computational Fluid Dynamics (CFD) integrated with a Fluid-Structure Interaction (FSI) framework. <i>Results:</i> The key analyses focused on the downstream shear stress distribution, vortex dynamics, clinically relevant hemodynamic indicators. When the valve was implanted along the axis of the aortic outflow tract (referred to as the AO angle), several benefits were observed. Blood flow penetrability improved, high shear stress regions were reduced, mechanical trauma to blood cells was significantly lessened. Quantitative metrics further demonstrated that the AO angle minimized values of Time-Averaged Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI) and Relative Residence Time (RRT). These metrics indicate more stable hemodynamics and a lower risk of ventricular wall inflammation and thrombosis. Furthermore, the Hemolysis Index (HI) reached its lowest level under the AO angle, suggesting optimal mitigation of hemolysis. This study systematically examines how the orientation of BMHV implantation affects LV hemodynamics. It identifies the AO angle as the most effective strategy for positioning. <i>Conclusions:</i> These findings provide quantitative evidence that can inform preoperative planning and support the advancement of precision-guided cardiac valve interventions based on hemodynamics considerations.

Authors

Institutions

Publication Details

Journal
Acta of Bioengineering and Biomechanics
Published
2025-09-03
DOI
https://doi.org/10.37190/abb/210002
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Bileaflet Mechanical Heart Valve implantation angle on left ventricular hemodynamics and blood cell damage

W. T. Geng, Yan Qiang, Liang Qi, Jiabao Qi et al.
Acta of Bioengineering and Biomechanics
Cardiovascular Function and Risk Factors
article

Impact of Bileaflet Mechanical Heart Valve implantation angle on left ventricular hemodynamics and blood cell damage

W. T. Geng, Yan Qiang, Liang Qi, Jiabao Qi, Zhixiong Li
article en

Abstract

<i>Purpose:</i> The implantation angle of Bileaflet Mechanical Heart Valve (BMHV) is critical issue in valve replacement surgery. Investigating the local hemodynamic characteristics and analyzing the postoperative flow dynamics can provide valuable insights for determining the optimal implantation angle, thereby offering clinical guidance for improved surgical outcomes. <i>Methods:</i> Three-dimensional anatomical model of the Left Ventricle (LV) and BMHV was reconstructed based on patient-specific medical imaging data and anatomical parameters. The hemodynamic effects of varying implantation angles were investigated using Computational Fluid Dynamics (CFD) integrated with a Fluid-Structure Interaction (FSI) framework. <i>Results:</i> The key analyses focused on the downstream shear stress distribution, vortex dynamics, clinically relevant hemodynamic indicators. When the valve was implanted along the axis of the aortic outflow tract (referred to as the AO angle), several benefits were observed. Blood flow penetrability improved, high shear stress regions were reduced, mechanical trauma to blood cells was significantly lessened. Quantitative metrics further demonstrated that the AO angle minimized values of Time-Averaged Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI) and Relative Residence Time (RRT). These metrics indicate more stable hemodynamics and a lower risk of ventricular wall inflammation and thrombosis. Furthermore, the Hemolysis Index (HI) reached its lowest level under the AO angle, suggesting optimal mitigation of hemolysis. This study systematically examines how the orientation of BMHV implantation affects LV hemodynamics. It identifies the AO angle as the most effective strategy for positioning. <i>Conclusions:</i> These findings provide quantitative evidence that can inform preoperative planning and support the advancement of precision-guided cardiac valve interventions based on hemodynamics considerations.

Acta of Bioengineering and BiomechanicsVol. 27(3)
Lanzhou University of Technology (CN), First Hospital of Lanzhou University (CN), Lanzhou University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 63%
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.