Double loop hydraulic and electrical control design and implementation to electrohydraulic tray system

This work deals with the design and implementation of a closed-loop electrohydraulic system control through a dual-loop controller design approach. The first loop controller is operates based on the electrohydraulic actuator displacement error i. e. the proportional valve control to regulate actuator displacement and the second loop based on regulating the speed of the prime mover to regulate the speed of the pump hence the flow towards the circuit. The valve control approach is mostly acceptable due to its performance accuracy and speed of response, nevertheless, it has experienced huge energy loss. The energy loss is to continue through the proportional valve. The pump-controlled system possesses less energy loss but is slow in response due to its complex control method. To avoid that problem in the present study a combined controlled method is implemented. The valve-controlled method is integrated with the pump-controlled method. The pump control is made operational through the speed control of the prime mover to avoid the problem of speed of response. In the present study, a fuzzy PID controller is implemented for the combined control approach.

Authors

Institutions

Publication Details

Published
2025-05-09
DOI
https://doi.org/10.1109/icepe65965.2025.11139661
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Double loop hydraulic and electrical control design and implementation to electrohydraulic tray system

Rakesh Roy, Bikash Kumar Sarkar, Vishal Chaudhary, John Kennedy Diengdoh et al.
Hydraulic and Pneumatic Systems
article

Double loop hydraulic and electrical control design and implementation to electrohydraulic tray system

Rakesh Roy, Bikash Kumar Sarkar, Vishal Chaudhary, John Kennedy Diengdoh, Banson MarkstarMawlein
article en

Abstract

This work deals with the design and implementation of a closed-loop electrohydraulic system control through a dual-loop controller design approach. The first loop controller is operates based on the electrohydraulic actuator displacement error i. e. the proportional valve control to regulate actuator displacement and the second loop based on regulating the speed of the prime mover to regulate the speed of the pump hence the flow towards the circuit. The valve control approach is mostly acceptable due to its performance accuracy and speed of response, nevertheless, it has experienced huge energy loss. The energy loss is to continue through the proportional valve. The pump-controlled system possesses less energy loss but is slow in response due to its complex control method. To avoid that problem in the present study a combined controlled method is implemented. The valve-controlled method is integrated with the pump-controlled method. The pump control is made operational through the speed control of the prime mover to avoid the problem of speed of response. In the present study, a fuzzy PID controller is implemented for the combined control approach.

National Institute of Technology Meghalaya (IN)
Openalex Percentile: Top 76%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Double loop hydraulic and electrical control design and implementation to electrohydraulic tray system — Rakesh Roy, Bikash Kumar Sarkar, et al. · (2025) | TGRS Research Map | TGRS