Evaluating Breast Cancer Intravoxel Incoherent Motion MRI Biomarkers across Software Platforms

Purpose To evaluate intravoxel incoherent motion (IVIM) biomarkers across different MRI vendors and software programs for breast cancer characterization in a two-site study. Materials and Methods This institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study included 106 patients (with 18 benign and 88 malignant lesions) who underwent bilateral diffusion-weighted imaging (DWI) between February 2009 and March 2013. DWI was performed using 1.5-T (<i>n</i> = 6) or 3-T MRI scanners from two vendors using single-shot spin-echo echo-planar imaging or twice-refocused, bipolar gradient single-shot turbo spin-echo readout with multiple <i>b</i> values between 0 and 1000 sec/mm<sup>2</sup>. IVIM parameters tissue diffusivity (<i>D<sub>t</sub></i>), perfusion fraction (<i>f<sub>p</sub></i>), pseudo-diffusivity (<i>D<sub>p</sub></i>), and their respective first-order radiomics were derived using two software packages (Igor; Wavemetrics, and Firevoxel; New York University). Bland-Altman analysis compared IVIM metrics from the two software programs. Histopathology was the reference standard, where logistic regressions with adjustments for site compared benign and malignant lesions. Least absolute shrinkage and selection operator (LASSO) penalized multivariable regression was performed first for metrics derived from each parameter separately, and then after incorporating metrics from all three parameters. Area under receiver operating characteristic (ROC) curve (AUC) ± standard error was used to quantify the diagnostic value. Performance was also evaluated using threefold cross-validation of the combined cohort. Results In total, 49 (mean age, 49 years ± 11 [SD]) and 57 (mean age, 48 years ± 10) female patients were enrolled from sites 1 and 2, respectively. Software 1 (Igor) and software 2 (Firevoxel) identified diagnostic biomarkers individually and in multivariable analysis. Tissue diffusivity exhibited the highest software consistency, with coefficients of variation of 4.8% and 2.8% (site 1 and site 2, respectively), followed by perfusion fraction (14.5% and 18.9%) and pseudo-diffusivity (36.9% and 19.8%). The highest performing metrics were <i>D<sub>t,min</sub></i> (AUC, 0.786 ± 0.05), <i>f<sub>p,max</sub></i> (AUC, 0.835 ± 0.04), and <i>D<sub>p,max</sub></i> (AUC, 0.804 ± 0.05) for software 1 and <i>D<sub>t,skew</sub></i> (AUC, 0.82 ± 0.05), <i>f<sub>p,max</sub></i> (AUC, 0.82 ± 0.046), and <i>D<sub>p,max</sub></i> (AUC, 0.75 ± 0.06) for software 2. Five metrics (<i>D<sub>t,min</sub>, D<sub>t,skew</sub>, f<sub>p,max</sub>, D<sub>p,min</sub>, D<sub>p,max</sub></i>) were included in the multivariable regression, achieving AUCs of 0.90 ± 0.03 and 0.90 ± 0.03 for software 1, and 0.84 ± 0.04 and 0.81 ± 0.05 for software 2, without and with cross-validation, respectively. Conclusion This study confirmed the translational potential of IVIM biomarkers for breast cancer characterization. <b>Keywords:</b> MR-Diffusion Weighted Imaging, Breast, Technology Assessment <i>Supplemental material is available for this article.</i> © RSNA, 2025.

Authors

Institutions

Publication Details

Journal
Radiology Imaging Cancer
Published
2025-09-01
DOI
https://doi.org/10.1148/rycan.240115
Citations
1
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Breast Cancer Intravoxel Incoherent Motion MRI Biomarkers across Software Platforms

Judith D. Goldberg, Eric E. Sigmund, Xiaochun Li, Katja Pinker et al.
1 citations
Radiology Imaging Cancer
MRI in cancer diagnosis
1.36
article

Evaluating Breast Cancer Intravoxel Incoherent Motion MRI Biomarkers across Software Platforms

Judith D. Goldberg, Eric E. Sigmund, Xiaochun Li, Katja Pinker, João V. Horvat, Henry Rusinek, Nima Gilani, Artem Mikheev, James S. Babb, Linda Moy, Sunitha B. Thakur, Dibash Basukala, Olivia M. Sutton, Gene Y. Cho
article en
1 citations

Abstract

Purpose To evaluate intravoxel incoherent motion (IVIM) biomarkers across different MRI vendors and software programs for breast cancer characterization in a two-site study. Materials and Methods This institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study included 106 patients (with 18 benign and 88 malignant lesions) who underwent bilateral diffusion-weighted imaging (DWI) between February 2009 and March 2013. DWI was performed using 1.5-T (<i>n</i> = 6) or 3-T MRI scanners from two vendors using single-shot spin-echo echo-planar imaging or twice-refocused, bipolar gradient single-shot turbo spin-echo readout with multiple <i>b</i> values between 0 and 1000 sec/mm<sup>2</sup>. IVIM parameters tissue diffusivity (<i>D<sub>t</sub></i>), perfusion fraction (<i>f<sub>p</sub></i>), pseudo-diffusivity (<i>D<sub>p</sub></i>), and their respective first-order radiomics were derived using two software packages (Igor; Wavemetrics, and Firevoxel; New York University). Bland-Altman analysis compared IVIM metrics from the two software programs. Histopathology was the reference standard, where logistic regressions with adjustments for site compared benign and malignant lesions. Least absolute shrinkage and selection operator (LASSO) penalized multivariable regression was performed first for metrics derived from each parameter separately, and then after incorporating metrics from all three parameters. Area under receiver operating characteristic (ROC) curve (AUC) ± standard error was used to quantify the diagnostic value. Performance was also evaluated using threefold cross-validation of the combined cohort. Results In total, 49 (mean age, 49 years ± 11 [SD]) and 57 (mean age, 48 years ± 10) female patients were enrolled from sites 1 and 2, respectively. Software 1 (Igor) and software 2 (Firevoxel) identified diagnostic biomarkers individually and in multivariable analysis. Tissue diffusivity exhibited the highest software consistency, with coefficients of variation of 4.8% and 2.8% (site 1 and site 2, respectively), followed by perfusion fraction (14.5% and 18.9%) and pseudo-diffusivity (36.9% and 19.8%). The highest performing metrics were <i>D<sub>t,min</sub></i> (AUC, 0.786 ± 0.05), <i>f<sub>p,max</sub></i> (AUC, 0.835 ± 0.04), and <i>D<sub>p,max</sub></i> (AUC, 0.804 ± 0.05) for software 1 and <i>D<sub>t,skew</sub></i> (AUC, 0.82 ± 0.05), <i>f<sub>p,max</sub></i> (AUC, 0.82 ± 0.046), and <i>D<sub>p,max</sub></i> (AUC, 0.75 ± 0.06) for software 2. Five metrics (<i>D<sub>t,min</sub>, D<sub>t,skew</sub>, f<sub>p,max</sub>, D<sub>p,min</sub>, D<sub>p,max</sub></i>) were included in the multivariable regression, achieving AUCs of 0.90 ± 0.03 and 0.90 ± 0.03 for software 1, and 0.84 ± 0.04 and 0.81 ± 0.05 for software 2, without and with cross-validation, respectively. Conclusion This study confirmed the translational potential of IVIM biomarkers for breast cancer characterization. <b>Keywords:</b> MR-Diffusion Weighted Imaging, Breast, Technology Assessment <i>Supplemental material is available for this article.</i> © RSNA, 2025.

Radiology Imaging CancerVol. 7(5)
Memorial Sloan Kettering Cancer Center (US), Columbia University Irving Medical Center (US), Mayo Clinic in Arizona (US), Orchid Pharma (India) (IN), Advanced Imaging Research (United States) (US), New York University (US), Columbia University (US)
National Institutes of Health, National Cancer Institute
Openalex Percentile: Top 16%
MRI in cancer diagnosis
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.