Development of a Sensitive Fluorimetric Method for Atomoxetine Determination in Tablets and Plasma Using a Dansyl Chloride Derivatization Approach

New, eco-friendly method for analyzing atomoxetine (AXT) was developed using dansyl chloride as a fluorescent derivative. The method demonstrated a linear range from 50.0 to 900.0 ng mL<sup>-1</sup> with a detection limit of 15.96 ng mL<sup>-1</sup>. It exhibited linearity (r<sup>2</sup> = 0.9995) and detection/quantification limits of 15.96 and 48.38 ng mL<sup>-1</sup>, respectively. The method demonstrated accuracy recoveries of 99.56% ± 1.11% to 100.67% ± 0.79% and precision ranging from 98.87% ± 1.91% to 102.54% ± 0.51% across 200.0 to 800.0 ng/mL. The proposed method, applied to capsules, spiked plasma, and real human plasma samples, demonstrated excellent accuracy, precision, and overall performance. Validation was performed according to International Conference on Harmonization (ICH) guidelines. The % Recovery ± SD of the proposed and reported methods was similar, with t-values (0.27-0.76) and F-values (1.37-3.17), confirming the method's reliability and consistency. Sustainability profiling using the RGB12 algorithm, Green Certificate, AGREE, SPMS, and BAGI tools showed a good sustainability profile.

Authors

Institutions

Publication Details

Journal
Luminescence
Published
2025-09-01
DOI
https://doi.org/10.1002/bio.70303
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Sensitive Fluorimetric Method for Atomoxetine Determination in Tablets and Plasma Using a Dansyl Chloride Derivatization Approach

Sultan Alshehri, Mohamed A. El Hamd, Reem H. Obaydo, Wael A. Mahdi et al.
Luminescence
Analytical Methods in Pharmaceuticals
article

Development of a Sensitive Fluorimetric Method for Atomoxetine Determination in Tablets and Plasma Using a Dansyl Chloride Derivatization Approach

Sultan Alshehri, Mohamed A. El Hamd, Reem H. Obaydo, Wael A. Mahdi, Ahmed Abdulhafez Hamad
article en

Abstract

New, eco-friendly method for analyzing atomoxetine (AXT) was developed using dansyl chloride as a fluorescent derivative. The method demonstrated a linear range from 50.0 to 900.0 ng mL<sup>-1</sup> with a detection limit of 15.96 ng mL<sup>-1</sup>. It exhibited linearity (r<sup>2</sup> = 0.9995) and detection/quantification limits of 15.96 and 48.38 ng mL<sup>-1</sup>, respectively. The method demonstrated accuracy recoveries of 99.56% ± 1.11% to 100.67% ± 0.79% and precision ranging from 98.87% ± 1.91% to 102.54% ± 0.51% across 200.0 to 800.0 ng/mL. The proposed method, applied to capsules, spiked plasma, and real human plasma samples, demonstrated excellent accuracy, precision, and overall performance. Validation was performed according to International Conference on Harmonization (ICH) guidelines. The % Recovery ± SD of the proposed and reported methods was similar, with t-values (0.27-0.76) and F-values (1.37-3.17), confirming the method's reliability and consistency. Sustainability profiling using the RGB12 algorithm, Green Certificate, AGREE, SPMS, and BAGI tools showed a good sustainability profile.

LuminescenceVol. 40(9)
Al-Azhar University (EG), South Valley University (EG), Shaqra University (SA), King Saud University (SA), Syrian Private University (SY), Assiut University (EG)
King Saud University
Openalex Percentile: Top 73%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a Sensitive Fluorimetric Method for Atomoxetine Determination in Tablets and Plasma Using a Dansyl Chloride Derivatization Approach — Sultan Alshehri, Mohamed A. El Hamd, et al. · Luminescence (2025) | TGRS Research Map | TGRS