The Influence of the Internal Design and Layer Thickness on the Accuracy of 3D-Printed Dental Models

This study investigated the effect of the internal design and layer thickness on 3D-printed dental models. The internal designs were classified based on the presence or absence of the palatal surface (Opened or Closed palate) and the outer wall thickness (1 mm, 3 mm, and Full). They were named as follows: O1, O3, OF, C1, C3, and CF. Based on the internal design and layer thickness (50 and 100 µm), a total of 12 experimental groups were created (n = 120). The control group was fabricated using dental stone (n = 10). The measurement sites were defined as follows: the mesiodistal width (MD) and occlusocervical height (OC) of the crown and the intercanine width (ICW) and intermolar width (IMW). Statistical significance was tested using a two-way ANOVA, one-way ANOVA, and independent sample <i>t</i>-test (α = 0.05). In comparisons with and without palatal surfaces, O3 and C3 showed a similar accuracy (<i>p</i> > 0.05) in the MD and OC, but C3 showed better (<i>p</i> < 0.05) or similar values (<i>p</i> > 0.05) than O3 in the ICW and IMW. Meanwhile, there was no significant difference between OF and CF in all measurement sites (<i>p</i> > 0.05). In comparisons of the outer wall thickness, CF showed a higher accuracy than C1 at all measurement sites (<i>p</i> < 0.05), whereas no statistical significance was observed between CF and C3 except for the ICW (<i>p</i> > 0.05). OF and CF did not show statistical significance according to the layer thickness at all measurement sites (<i>p</i> > 0.05). In all measurement sites except OC, the experimental group showed a superior (<i>p</i> < 0.05) or similar accuracy than the control group (<i>p</i> > 0.05). Within the limitations of this study, a 3 mm outer wall, including the palatal surface, and a 50 µm layer thickness is recommended as the optimal 3D printing condition for dental model fabrication.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-09-05
DOI
https://doi.org/10.3390/ma18174173
Citations
1
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
1.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Influence of the Internal Design and Layer Thickness on the Accuracy of 3D-Printed Dental Models

Ji‐Hoon Ahn, Jae-Won Choi
1 citations
Materials
Dental materials and restorations
1.68
article

The Influence of the Internal Design and Layer Thickness on the Accuracy of 3D-Printed Dental Models

Ji‐Hoon Ahn, Jae-Won Choi
article en
1 citations

Abstract

This study investigated the effect of the internal design and layer thickness on 3D-printed dental models. The internal designs were classified based on the presence or absence of the palatal surface (Opened or Closed palate) and the outer wall thickness (1 mm, 3 mm, and Full). They were named as follows: O1, O3, OF, C1, C3, and CF. Based on the internal design and layer thickness (50 and 100 µm), a total of 12 experimental groups were created (n = 120). The control group was fabricated using dental stone (n = 10). The measurement sites were defined as follows: the mesiodistal width (MD) and occlusocervical height (OC) of the crown and the intercanine width (ICW) and intermolar width (IMW). Statistical significance was tested using a two-way ANOVA, one-way ANOVA, and independent sample <i>t</i>-test (α = 0.05). In comparisons with and without palatal surfaces, O3 and C3 showed a similar accuracy (<i>p</i> > 0.05) in the MD and OC, but C3 showed better (<i>p</i> < 0.05) or similar values (<i>p</i> > 0.05) than O3 in the ICW and IMW. Meanwhile, there was no significant difference between OF and CF in all measurement sites (<i>p</i> > 0.05). In comparisons of the outer wall thickness, CF showed a higher accuracy than C1 at all measurement sites (<i>p</i> < 0.05), whereas no statistical significance was observed between CF and C3 except for the ICW (<i>p</i> > 0.05). OF and CF did not show statistical significance according to the layer thickness at all measurement sites (<i>p</i> > 0.05). In all measurement sites except OC, the experimental group showed a superior (<i>p</i> < 0.05) or similar accuracy than the control group (<i>p</i> > 0.05). Within the limitations of this study, a 3 mm outer wall, including the palatal surface, and a 50 µm layer thickness is recommended as the optimal 3D printing condition for dental model fabrication.

MaterialsVol. 18(17)
Catholic University of Pusan (KR)
National Research Foundation, Catholic University of Pusan, National Research Foundation of Korea
Openalex Percentile: Top 15%
Dental materials and restorations
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.