Extending the Linear Dynamic Range of Single Particle ICP-MS for the Quantification of Microplastics

In response to the growing concern of microplastics (1 μm to 5 mm) accumulation affecting human health, the development of analytical methods continues to be critical for the detection and characterization of microplastic particles. In this context, pursuing exceptional particle detection capability down to practical low levels and rapid analyses with high sample throughput makes single particle inductively coupled plasma mass spectrometry (spICP-MS) very attractive for microplastics analysis. Existing spICP-MS-based studies have routinely shown limitations in the accurate sizing and quantification of particle number concentration through targeting carbon content, with reported size limits of detection in the range of 0.62 to 1.8 μm and a substantial reduction in the transport of particles larger than 3 μm. In this work, the linear dynamic range of spICP-MS for the accurate quantification of polystyrene microparticles (PS MPs) via the monitoring of their carbon content (<sup>13</sup>C<sup>+</sup>) is extended to larger particle sizes (5 μm) through using a high efficiency sample introduction system with rigorous optimization of the <sup>13</sup>C signal and operating at a lowered nebulizer gas flow to improve sample transport of larger particles to the plasma. Reliable quantification of particle number concentration (PNC), accepted as falling within 20% of expected particle stock concentrations, was achieved through a 20% lowered nebulizer gas flow for a full suite of commercial PS MPs ranging from 2 to 5 μm as well as a 2.2 and 4.8 μm PS MP contained within mixtures of the two materials, regardless of PNC ratio.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-09-05
DOI
https://doi.org/10.1021/acs.analchem.5c03552
Citations
2
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extending the Linear Dynamic Range of Single Particle ICP-MS for the Quantification of Microplastics

Monique E. Johnson, George C. Caceres, Antonio R. Montoro Bustos, Sang Bok Lee et al.
2 citations
Analytical Chemistry
Microplastics and Plastic Pollution
1.01
article

Extending the Linear Dynamic Range of Single Particle ICP-MS for the Quantification of Microplastics

Monique E. Johnson, George C. Caceres, Antonio R. Montoro Bustos, Sang Bok Lee, John L. Molloy
article en
2 citations

Abstract

In response to the growing concern of microplastics (1 μm to 5 mm) accumulation affecting human health, the development of analytical methods continues to be critical for the detection and characterization of microplastic particles. In this context, pursuing exceptional particle detection capability down to practical low levels and rapid analyses with high sample throughput makes single particle inductively coupled plasma mass spectrometry (spICP-MS) very attractive for microplastics analysis. Existing spICP-MS-based studies have routinely shown limitations in the accurate sizing and quantification of particle number concentration through targeting carbon content, with reported size limits of detection in the range of 0.62 to 1.8 μm and a substantial reduction in the transport of particles larger than 3 μm. In this work, the linear dynamic range of spICP-MS for the accurate quantification of polystyrene microparticles (PS MPs) via the monitoring of their carbon content (<sup>13</sup>C<sup>+</sup>) is extended to larger particle sizes (5 μm) through using a high efficiency sample introduction system with rigorous optimization of the <sup>13</sup>C signal and operating at a lowered nebulizer gas flow to improve sample transport of larger particles to the plasma. Reliable quantification of particle number concentration (PNC), accepted as falling within 20% of expected particle stock concentrations, was achieved through a 20% lowered nebulizer gas flow for a full suite of commercial PS MPs ranging from 2 to 5 μm as well as a 2.2 and 4.8 μm PS MP contained within mixtures of the two materials, regardless of PNC ratio.

Analytical ChemistryVol. 97(36)
National Institute of Standards and Technology (US), Material Measurement Laboratory (US), University of Maryland, College Park (US)
Openalex Percentile: Top 23%
Microplastics and Plastic Pollution
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.