Real-Time Optical and Acoustic Characterization of Phase-Shift Droplets for Drug-Delivery Applications

Phase-shift droplets undergoing acoustic droplet vaporization (ADV) offer a promising approach for ultrasound-mediated drug delivery, enabling the spatiotemporally controlled release of therapeutic payloads. A comprehensive understanding of their behavior, through both optical and acoustic methods, is essential for optimizing the therapeutic efficacy. In this study, we investigated the effects of driving pressure, pulse duration, and bulk boiling point of perfluorocarbon droplets on ADV dynamics, payload release, and acoustic emissions. We employed ultra-high-speed brightfield [10 million frames per second (Mfps)], fluorescence (2 Mfps), and confocal microscopy (1 fps) to capture ADV and real-time payload release in fibrin-based hydrogels. During ADV, payload release velocities reached 2-4 m/s, slowing to 0.6-2.7 μm/s post ultrasound. While the cycle number and pressure affected early bubble expansion and acoustic output, long-term bubble behavior and release kinetics were governed by the droplet's thermophysical properties. Ultra-high-speed imaging revealed a direct coupling between bubble dynamics and payload release during ultrasound exposure, with release continuing via diffusion after ultrasound. Notably, payload release rates post-ultrasound exceeded bubble growth rates. Additionally, acoustic emissions, recorded via passive cavitation detection, increased with both pressure and pulse number but decreased in droplets with higher bulk boiling points. These findings underscore the importance of integrating multimodal imaging methods to elucidate ADV mechanisms and design effective hydrogel-based drug-delivery systems.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-09-05
DOI
https://doi.org/10.1021/acsami.5c11300
Citations
2
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Optical and Acoustic Characterization of Phase-Shift Droplets for Drug-Delivery Applications

Jonathan B. Estrada, Mitra Aliabouzar, Mario L. Fabiilli, Bachir A. Abeid et al.
2 citations
ACS Applied Materials & Interfaces
Ultrasound and Hyperthermia Applications
1.35
article

Real-Time Optical and Acoustic Characterization of Phase-Shift Droplets for Drug-Delivery Applications

Jonathan B. Estrada, Mitra Aliabouzar, Mario L. Fabiilli, Bachir A. Abeid, Ze Qi Chan
article en
2 citations

Abstract

Phase-shift droplets undergoing acoustic droplet vaporization (ADV) offer a promising approach for ultrasound-mediated drug delivery, enabling the spatiotemporally controlled release of therapeutic payloads. A comprehensive understanding of their behavior, through both optical and acoustic methods, is essential for optimizing the therapeutic efficacy. In this study, we investigated the effects of driving pressure, pulse duration, and bulk boiling point of perfluorocarbon droplets on ADV dynamics, payload release, and acoustic emissions. We employed ultra-high-speed brightfield [10 million frames per second (Mfps)], fluorescence (2 Mfps), and confocal microscopy (1 fps) to capture ADV and real-time payload release in fibrin-based hydrogels. During ADV, payload release velocities reached 2-4 m/s, slowing to 0.6-2.7 μm/s post ultrasound. While the cycle number and pressure affected early bubble expansion and acoustic output, long-term bubble behavior and release kinetics were governed by the droplet's thermophysical properties. Ultra-high-speed imaging revealed a direct coupling between bubble dynamics and payload release during ultrasound exposure, with release continuing via diffusion after ultrasound. Notably, payload release rates post-ultrasound exceeded bubble growth rates. Additionally, acoustic emissions, recorded via passive cavitation detection, increased with both pressure and pulse number but decreased in droplets with higher bulk boiling points. These findings underscore the importance of integrating multimodal imaging methods to elucidate ADV mechanisms and design effective hydrogel-based drug-delivery systems.

ACS Applied Materials & InterfacesVol. 17(37)
University of Michigan (US)
University of Michigan, National Heart, Lung, and Blood Institute
Openalex Percentile: Top 18%
Ultrasound and Hyperthermia Applications
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.