Results of Provincial Health Institutions Participating in Individual Monitoring Intercomparisons—China, 2022 to 2024
To improve monitoring capabilities, China CDC organized individual monitoring intercomparisons, which provincial health institutions participated in from 2022 to 2024. The irradiation schemes and evaluation criteria were designed in accordance with GBZ 207-2016, "Testing criteria of personnel dosimetry performance for external exposure." The Type II (photon) test specified in the standard was selected as the intercomparison type, with Hp (10) as the target quantity. Each institution submitted 21 dosimeters for participation in the intercomparison exercises. Irradiation schemes with various radiation quality and incident angles were randomly assigned to each participant. Out of 580 P i values, 82.6% (479) were classified as excellent, and 96.9% (562) met the qualification criteria. Four institutions reported 18 unqualified P i values. These demonstrate the reliable performance of the dosimetry systems. These intercomparisons helped participants identify system deviations and enabled radiation health administrative departments to grasp the capabilities of each institution, thus strengthening the protection of the occupational health of radiological workers.
Authors
- Yanqiu Ding
- Pin Gao
- Kaiyi Wang (ORCID: https://orcid.org/0000-0003-3012-7099)
- Wen Guo
Institutions
- National Institute for Radiological Protection (CN)
Publication Details
- Journal
- Health Physics
- Published
- 2025-09-05
- DOI
- https://doi.org/10.1097/hp.0000000000002024
- Primary Topic
- Radiation Dose and Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.00