Analysis of a Trip Accident Caused by Short Circuit Impact of 35kV Side Outlet Cable of the Main Transformer

Power cable is the backbone of the power system, once the failure will produce significant losses. The analysis of power system faults can not only prevent similar faults from happening again, reduce the loss caused by power faults, but also find the hidden dangers of transmission lines in time, so as to prevent them before they occur. In this paper, a trip accident of main transformer caused by cable short circuit impact is introduced in detail. Firstly, the anti-short circuit ability of transformer is analyzed, and the influence of transformer is excluded. Secondly, the fault development process of cable is analyzed by the fault record wave shape at the protection action time. Finally, the cause of the failure was determined by disassembling the cable. Based on the above research process, in order to prevent cable faults, this paper puts forward suggestions on the safe operation and fault prevention of cable lines.

Authors

Institutions

Publication Details

Published
2025-06-28
DOI
https://doi.org/10.1109/icipca65645.2025.11138908
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of a Trip Accident Caused by Short Circuit Impact of 35kV Side Outlet Cable of the Main Transformer

G. Zhu, Hang Lü, Yuenan Guo, Zhongzhi Qu et al.
High voltage insulation and dielectric phenomena
article

Analysis of a Trip Accident Caused by Short Circuit Impact of 35kV Side Outlet Cable of the Main Transformer

G. Zhu, Hang Lü, Yuenan Guo, Zhongzhi Qu, Lei Yu, Dewen Zhang
article en

Abstract

Power cable is the backbone of the power system, once the failure will produce significant losses. The analysis of power system faults can not only prevent similar faults from happening again, reduce the loss caused by power faults, but also find the hidden dangers of transmission lines in time, so as to prevent them before they occur. In this paper, a trip accident of main transformer caused by cable short circuit impact is introduced in detail. Firstly, the anti-short circuit ability of transformer is analyzed, and the influence of transformer is excluded. Secondly, the fault development process of cable is analyzed by the fault record wave shape at the protection action time. Finally, the cause of the failure was determined by disassembling the cable. Based on the above research process, in order to prevent cable faults, this paper puts forward suggestions on the safe operation and fault prevention of cable lines.

State Grid Corporation of China (China) (CN), Harbin Electric Corporation (China) (CN), Heilongjiang Electric Power Workers University (CN)
Openalex Percentile: Top 82%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.