Research on Advanced Modular De-icing Technology for 500-kV Transmission Lines

With the intensification of global climate anomalies, the impact of transmission line icing on grid security and stability has become increasingly severe. Mobile DC de-icing devices have achieved mature application in transmission lines at 220 kV and below. However, when confronted with 500-kV transmission lines characterized by longer spans, larger conductor cross-sections, and multi-bundle configurations, existing mobile DC de-icing units fail to meet the demanding current, voltage, and capacity requirements for effective ice mitigation. This paper demonstrates the necessity of researching mobile DC de-icing solutions for 500kV grids and proposes several modular mobile de-icing topologies addressing critical implementation challenges. Comparative analysis reveals that the parallel operation topology outperforms others in 500-kV de-icing scenarios. These findings provide crucial technical support for implementing mobile de-icing on 500-kV transmission networks.

Authors

Institutions

Publication Details

Published
2025-06-20
DOI
https://doi.org/10.1109/icetac65964.2025.11144246
Primary Topic
Icing and De-icing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Advanced Modular De-icing Technology for 500-kV Transmission Lines

Peng Jin, Zehong Chen, Haiwei Yang, Chunlei Wang et al.
Icing and De-icing Technologies
article

Research on Advanced Modular De-icing Technology for 500-kV Transmission Lines

Peng Jin, Zehong Chen, Haiwei Yang, Chunlei Wang, Yilin Zhang, Tianbao Li, X. Wang, LU Xue-li
article en

Abstract

With the intensification of global climate anomalies, the impact of transmission line icing on grid security and stability has become increasingly severe. Mobile DC de-icing devices have achieved mature application in transmission lines at 220 kV and below. However, when confronted with 500-kV transmission lines characterized by longer spans, larger conductor cross-sections, and multi-bundle configurations, existing mobile DC de-icing units fail to meet the demanding current, voltage, and capacity requirements for effective ice mitigation. This paper demonstrates the necessity of researching mobile DC de-icing solutions for 500kV grids and proposes several modular mobile de-icing topologies addressing critical implementation challenges. Comparative analysis reveals that the parallel operation topology outperforms others in 500-kV de-icing scenarios. These findings provide crucial technical support for implementing mobile de-icing on 500-kV transmission networks.

Hunan Xiangdian Test Research Institute (China) (CN), Jilin Electric Power Research Institute (China) (CN)
State Grid Corporation of China
Openalex Percentile: Top 68%
Icing and De-icing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Advanced Modular De-icing Technology for 500-kV Transmission Lines — Peng Jin, Zehong Chen, et al. · (2025) | TGRS Research Map | TGRS