Multiplexed Microphotonic Ring Resonator Platform for Simultaneous Detection of SARS-CoV-2 Spike Protein and Respiratory Syncytial Virus-F Protein
The persistent burden imposed by SARS-CoV-2, respiratory syncytial virus (RSV), and other respiratory viruses highlights the demand for real-time, label-free diagnostics capable of multi-pathogen detection. Despite numerous proposals, existing biosensors have yet to achieve the trifecta of sub-nanomolar sensitivity, simultaneous targeting, and a truly compact footprint. Here, we show a multiplexed photonic biosensor based on cascaded microring resonators that can detect two different viral glycoproteins, such as the SARS-CoV-2 spike protein and the RSV-F protein, at sub-nanomolar concentrations. Three strip-waveguide rings (radii = 99, 100, 101 μm; TE mode at 1310 nm) were designed via finite-element modelling and fabricated on a Si<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub>N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sub>-on-insulator platform using e-beam lithography and inductively coupled plasma reactive ion etching (ICP-RIE). Preliminary results demonstrate a quality factor of the order of 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sup> and a mean bulk sensitivity value of 150 nm/RIU, evaluated in gradually concentrated ethanol solutions flowing on the sensor surface. A common bus waveguide enables wavelength-division multiplexing (WDM). Selective, oriented immobilization of anti-spike and anti-F antibodies is achieved through a protein A interfacial layer, while the central ring is intentionally left bare as an on-chip reference. By sweeping the wavelength of a continuous wave (CW) laser across each resonance, real-time resonance shifts are monitored and quantified via Lorentzian peak fitting. By functionalizing distinct rings with viral proteins-specific antibodies, our chip achieves detection limits of approximately 0.16 nM for the SARS-CoV-2 spike protein and 0.14 nM for the RSV-F protein, matching or surpassing the performance of conventional single-target optical biosensors. Our design allows the analysis of multiple viral antigens in parallel, reducing sample volume and overall test duration. Moreover, an on-chip reference ring ensures robust signal stability by compensating for non-specific effects, thereby enhancing accuracy and reproducibility. These findings underscore the promise of integrated photonics to reshape point-of-care diagnostics, especially in decentralized or resource-limited settings. We anticipate that this platform’s versatility can be extended to detect additional pathogens or biomolecules, providing a scalable and cost-effective tool for rapid clinical decision-making and epidemiological surveillance.
Authors
- M Gómez-Gómez
- Francesco Dell’Olio (ORCID: https://orcid.org/0000-0001-9874-5008)
- Alejandro Martı́nez (ORCID: https://orcid.org/0000-0001-5448-0140)
- Annabella la Grasta (ORCID: https://orcid.org/0009-0004-1230-5853)
- Amadeu Griol
- E. Barrio Gómez
Institutions
- Universitat Politècnica de València (ES)
- Polytechnic University of Bari (IT)
Publication Details
- Journal
- IEEE Sensors Journal
- Published
- 2025-09-05
- DOI
- https://doi.org/10.1109/jsen.2025.3604239
- Citations
- 1
- Primary Topic
- Photonic and Optical Devices
- Type
- article
- Field-Weighted Citation Impact
- 0.73
Funders
- European Commission