Development of an in-vacuum long trace profiler for <i>in situ</i> measurement of optical components

In this work, we developed a vacuum-compatible long trace profiler (LTP) for in situ metrology of ultra-precise x-ray optics within synchrotron vacuum chambers. Although traditional LTPs operate ex situ under atmospheric pressure, earlier optical setups-such as that by Qian et al.-performed in situ distortion measurements by directing laser beams through vacuum viewports. While these configurations enabled in situ monitoring of mirror deformation, their accuracy was constrained by optical distortions from vacuum windows and by beam deviations caused by air turbulence. To overcome these limitations, we developed a fully in-vacuum LTP system installed directly inside the vacuum chamber, fully compatible with ultrahigh vacuum (UHV) conditions (<1 × 10-8 Torr). Based on the original Takacs LTP design, the system incorporates a vacuum-compatible CMOS sensor, an external laser to reduce heat and weight, and a motorized four-axis alignment stage. This system is designed to measure low-spatial-frequency slope error, which is critical for evaluating optical figure quality. Performance was validated under identical atmospheric conditions using a conventional LTP for comparison. Under identical conditions, the in-vacuum LTP measured slope errors of 100 nrad RMS (flat) and 200 nrad RMS (curved). However, measurable deviations in curvature radius and coma coefficient were observed, attributed to stage wobble and lens aberrations. These findings confirm baseline performance and demonstrate the system's feasibility for UHV-compatible slope metrology. The in-vacuum LTP is intended to support real-time slope monitoring and feedback correction of active optical components during operation at synchrotron beamlines.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-09-01
DOI
https://doi.org/10.1063/5.0256054
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an in-vacuum long trace profiler for in situ measurement of optical components

Gung-Chian Yin, Ming-Ying Hsu, Shang-Wei Lin, Bo-Yi Chen et al.
Review of Scientific Instruments
Advanced X-ray Imaging Techniques
article

Development of an in-vacuum long trace profiler for in situ measurement of optical components

Gung-Chian Yin, Ming-Ying Hsu, Shang-Wei Lin, Bo-Yi Chen, Chao-Chih Chiu, Chia-Feng Chang
article en

Abstract

In this work, we developed a vacuum-compatible long trace profiler (LTP) for in situ metrology of ultra-precise x-ray optics within synchrotron vacuum chambers. Although traditional LTPs operate ex situ under atmospheric pressure, earlier optical setups-such as that by Qian et al.-performed in situ distortion measurements by directing laser beams through vacuum viewports. While these configurations enabled in situ monitoring of mirror deformation, their accuracy was constrained by optical distortions from vacuum windows and by beam deviations caused by air turbulence. To overcome these limitations, we developed a fully in-vacuum LTP system installed directly inside the vacuum chamber, fully compatible with ultrahigh vacuum (UHV) conditions (<1 × 10-8 Torr). Based on the original Takacs LTP design, the system incorporates a vacuum-compatible CMOS sensor, an external laser to reduce heat and weight, and a motorized four-axis alignment stage. This system is designed to measure low-spatial-frequency slope error, which is critical for evaluating optical figure quality. Performance was validated under identical atmospheric conditions using a conventional LTP for comparison. Under identical conditions, the in-vacuum LTP measured slope errors of 100 nrad RMS (flat) and 200 nrad RMS (curved). However, measurable deviations in curvature radius and coma coefficient were observed, attributed to stage wobble and lens aberrations. These findings confirm baseline performance and demonstrate the system's feasibility for UHV-compatible slope metrology. The in-vacuum LTP is intended to support real-time slope monitoring and feedback correction of active optical components during operation at synchrotron beamlines.

Review of Scientific InstrumentsVol. 96(9)
National Synchrotron Radiation Research Center (TW)
National Synchrotron Radiation Research Center
Openalex Percentile: Top 70%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.