Determination of the inter-observer and inter-scanner variability in the measurement of the renal resistive and renal pulsatility indices in dogs

Renal Resistive Index (RRI) and Renal Pulsatility Index (RPI) are currently used in the diagnosis of ureteral obstruction, early diagnosis and follow-up of acute kidney injury, assessment of chronic kidney disease, and evaluation of transplanted kidneys. However, their inter-observer and inter-scanner variability has not been investigated in dogs, limiting the accuracy and clinical applicability of these indices. The objectives of this cross-sectional observational prospective study were to assess the inter-observer and inter-scanner variability of RRI and RPI and to determine whether operator experience influences measurement accuracy. RRI and RPI were measured in the left kidney of 10 client-owned dogs by four different operators with varying levels of experience, using two different ultrasound scanners. The intraclass correlation coefficient (ICC) between the two ultrasound scanners for both RRI and RPI were good to excellent in all four observers (ICC > 0.75 and p < 0.05). Similarly, a good to excellent correlation coefficient was observed between the measurements of the four operators for both indices across each ultrasound scanner (ICC > 0.75 and p < 0.05). These findings indicate that RRI and RPI are feasible and reproducible measurements with good inter-scanner and inter-observer agreement, regardless of operator experience. However, achieving high reproducibility requires adequate training and the use of a standardized protocol with strict but adaptable settings tailored to each patient's characteristics.

Authors

Institutions

Publication Details

Journal
Research in Veterinary Science
Published
2025-09-04
DOI
https://doi.org/10.1016/j.rvsc.2025.105882
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the inter-observer and inter-scanner variability in the measurement of the renal resistive and renal pulsatility indices in dogs

Eduardo Pérez, María Ángeles Daza, Elena Mínguez-Pereira, Laura Martín-Carrasco et al.
1 links
Research in Veterinary Science
Hemodynamic Monitoring and Therapy
article

Determination of the inter-observer and inter-scanner variability in the measurement of the renal resistive and renal pulsatility indices in dogs

Eduardo Pérez, María Ángeles Daza, Elena Mínguez-Pereira, Laura Martín-Carrasco, H. Garcia, Jorge Ortiz-Gutiérrez, Miriam Portero-Fuentes
article en

Abstract

Renal Resistive Index (RRI) and Renal Pulsatility Index (RPI) are currently used in the diagnosis of ureteral obstruction, early diagnosis and follow-up of acute kidney injury, assessment of chronic kidney disease, and evaluation of transplanted kidneys. However, their inter-observer and inter-scanner variability has not been investigated in dogs, limiting the accuracy and clinical applicability of these indices. The objectives of this cross-sectional observational prospective study were to assess the inter-observer and inter-scanner variability of RRI and RPI and to determine whether operator experience influences measurement accuracy. RRI and RPI were measured in the left kidney of 10 client-owned dogs by four different operators with varying levels of experience, using two different ultrasound scanners. The intraclass correlation coefficient (ICC) between the two ultrasound scanners for both RRI and RPI were good to excellent in all four observers (ICC > 0.75 and p < 0.05). Similarly, a good to excellent correlation coefficient was observed between the measurements of the four operators for both indices across each ultrasound scanner (ICC > 0.75 and p < 0.05). These findings indicate that RRI and RPI are feasible and reproducible measurements with good inter-scanner and inter-observer agreement, regardless of operator experience. However, achieving high reproducibility requires adequate training and the use of a standardized protocol with strict but adaptable settings tailored to each patient's characteristics.

Research in Veterinary ScienceVol. 196
Universidad Complutense de Madrid (ES)
Openalex Percentile: Top 62%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.