Automation of adaptive controller design for power generation from renewable energy sources using multiple chaotic maps-based Harris hawk optimizer

Renewable energy generation systems are expanding fast worldwide. These systems utilize inverters along with a filter to inject power into the grid. Among commonly used filters, the inductor-capacitor-inductor (LCL) filter stands out due to its characteristics. However, it has an inherent peak of resonance close to the frequency of interest that may make the system unstable. Active damping strategies come in to solve it. In this sense, direct adaptive controllers present advantageous benefits in comparison to controllers with fixed gains because they can update their gains online in response to changes in system parameters and exogenous disturbances. However, adaptive controllers have many parameters to design, requiring a very experienced designer to configure them to obtain satisfactory performance. In this context, this work proposes a procedure to parametrize adaptive controllers using a new multiple-chaotic maps-based Harris hawk optimizer (HHO). The parametrization procedure considers the controller stability constraints, tracking errors, and physical control action synthetization. The systematic methodology is evaluated on a robust adaptive model reference proportional integral controller applied to grid-injected current control of a voltage source inverter with an LCL filter. The proposed method surpasses the performance of 9 chaotic HHO. High-fidelity simulation results, considering a Kalman filter-based phase-locked loop and space vector modulation, indicate the high performance of the optimized controller, where the transient regimes end between one quarter and half of a grid cycle, and the steady-state total harmonic distortion (THD) is around 2.5%. • A novel variant of HHO based on multiple chaos maps. • An easy-to-use procedure for tuning advanced adaptive controllers. • An optimized adaptive controller for grid-tied VSI with an LCL filter.

Authors

Institutions

Publication Details

Journal
Next Energy
Published
2025-09-04
DOI
https://doi.org/10.1016/j.nxener.2025.100411
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automation of adaptive controller design for power generation from renewable energy sources using multiple chaotic maps-based Harris hawk optimizer

Marlon Soares Sigales, Paulo Jefferson Dias de Oliveira Evald, Elmer A. G. Peñaloza, Jaime C. Fonseca et al.
Next Energy
Microgrid Control and Optimization
article

Automation of adaptive controller design for power generation from renewable energy sources using multiple chaotic maps-based Harris hawk optimizer

Marlon Soares Sigales, Paulo Jefferson Dias de Oliveira Evald, Elmer A. G. Peñaloza, Jaime C. Fonseca, Guilherme Vieira Hollweg
article en

Abstract

Renewable energy generation systems are expanding fast worldwide. These systems utilize inverters along with a filter to inject power into the grid. Among commonly used filters, the inductor-capacitor-inductor (LCL) filter stands out due to its characteristics. However, it has an inherent peak of resonance close to the frequency of interest that may make the system unstable. Active damping strategies come in to solve it. In this sense, direct adaptive controllers present advantageous benefits in comparison to controllers with fixed gains because they can update their gains online in response to changes in system parameters and exogenous disturbances. However, adaptive controllers have many parameters to design, requiring a very experienced designer to configure them to obtain satisfactory performance. In this context, this work proposes a procedure to parametrize adaptive controllers using a new multiple-chaotic maps-based Harris hawk optimizer (HHO). The parametrization procedure considers the controller stability constraints, tracking errors, and physical control action synthetization. The systematic methodology is evaluated on a robust adaptive model reference proportional integral controller applied to grid-injected current control of a voltage source inverter with an LCL filter. The proposed method surpasses the performance of 9 chaotic HHO. High-fidelity simulation results, considering a Kalman filter-based phase-locked loop and space vector modulation, indicate the high performance of the optimized controller, where the transient regimes end between one quarter and half of a grid cycle, and the steady-state total harmonic distortion (THD) is around 2.5%. • A novel variant of HHO based on multiple chaos maps. • An easy-to-use procedure for tuning advanced adaptive controllers. • An optimized adaptive controller for grid-tied VSI with an LCL filter.

Next EnergyVol. 9
Universidade Federal de Pelotas (BR), University of Michigan–Dearborn (US)
Openalex Percentile: Top 71%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.