Combined Experimental and Numerical Study on Wind Resistance of a Long-Span Steel Truss Arch Bridge During Construction
Introduction: During construction, long-span steel truss arch bridges exhibit complex structural behaviors and are vulnerable to wind-induced vibrations. Effective evaluation of wind resistance during critical construction stages remains challenging. The objective of this research is to investigate the wind-resistant performance of a large-scale steel truss arch bridge during construction using experimental and numerical approaches, with insights into recent relevant patents on wind-resistant measures for bridge construction. Methods: A large-scale aeroelastic full-bridge wind tunnel test was performed alongside refined finite element (FE) analyses of different construction stages. FE models were established to characterize the dynamic behavior evolution throughout construction. Wind-induced responses under critical construction scenarios, particularly at the maximum cantilever state, were experimentally measured and numerically validated. Results: Results indicated significant variations in structural dynamic characteristics throughout different construction stages. Among these, the maximum cantilever stage exhibited the most pronounced wind-induced response, with increased sensitivity to wind loading. Combining wind tunnel experiments with FE analysis provided an accurate assessment of the bridge's wind resistance. The effectiveness of proposed wind-resistant measures specifically designed for construction phases, aligned with recent patented technologies, was demonstrated through substantial reductions in wind-induced vibrations. Discussion: The comparative study between experimental and numerical methods highlights the complementary strengths of both approaches in capturing wind-induced responses during construction. The proposed mitigation strategies not only align with patented wind control technologies but also provide practical insight into construction-stage wind safety for similar bridge types. Conclusion: The integrated methodology employing wind tunnel tests and finite element simulations effectively assessed and enhanced the wind resistance performance during the construction of long-span steel truss arch bridges. Findings of this study offer valuable guidance for wind-resistant design and construction management of similar large-scale bridge projects, contributing to advancements outlined in recent patents related to wind mitigation technologies for bridge engineering.
Authors
- Xin Xiao (ORCID: https://orcid.org/0000-0003-0718-2591)
- Shan Gao (ORCID: https://orcid.org/0000-0003-0262-4549)
- Jun Liu (ORCID: https://orcid.org/0009-0002-9672-163X)
- Tao Liu (ORCID: https://orcid.org/0000-0003-2713-3674)
Institutions
- Foshan University (CN)
- Southwest Petroleum University (CN)
- Shenzhen Metro (China) (CN)
- Yueyang Changling Equipment Research Institute (China) (CN)
- Southwest Jiaotong University Hope College
- Southwest Jiaotong University (CN)
Publication Details
- Journal
- Recent Patents on Engineering
- Published
- 2025-09-04
- DOI
- https://doi.org/10.2174/0118722121413761250819094729
- Primary Topic
- Structural Engineering and Vibration Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00