Residual motion artifact removal enables dynamic <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si8.svg" display="inline" id="d1e260"> <mml:mi mathvariant="normal">μ</mml:mi> </mml:math> MRI of a behaving Pachnoda marginata

Microscopic magnetic resonance imaging, also referred to as μMRI, is a non-invasive imaging modality ideal for studying small live model organisms. However, μMRI raw data acquisition is inherently sequential and slow in comparison to the biomechanics timescale of the behaving organism, leading to motion artifacts upon image reconstruction. Recently, we have developed an integrated spherical treadmill with a prospectively triggered k-space acquisition technique to provide position consistency for studying live, behaving insect using μMRI. Despite this advancement, behaving insects on the treadmill still exhibited motion artifacts due to tethered locomotion being coupled with internal organ dynamics. Here, we are addressing the large-scale non-rigid nature of the abdominal motion of the behaving insect by developing a fully retrospective gating strategy using the motion information obtained from an in-situ computer vision system. Residual motion artifacts persisting after gating are effectively managed through a deep learning technique. We trained a U-Net-based deep convolutional neural network using pairs of simulated motion-corrupted and motion-free images as a supervised image-to-image translation problem. Our results demonstrate that combining retrospective gated μMRI reconstruction with a deep learning residual motion compensation technique can significantly reduce the motional artifacts, thereby paving the way for the non-invasive dynamic imaging studies of behaving organisms with 117 μm in-plane resolution.

Authors

Institutions

Publication Details

Journal
Journal of Magnetic Resonance
Published
2025-09-04
DOI
https://doi.org/10.1016/j.jmr.2025.107954
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Residual motion artifact removal enables dynamic <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si8.svg" display="inline" id="d1e260"> <mml:mi mathvariant="normal">μ</mml:mi> </mml:math> MRI of a behaving Pachnoda marginata

Mazin Jouda, Ulrike Wallrabe, Jan Gerrit Korvink, Ajmal Chenakkara
Journal of Magnetic Resonance
Advanced MRI Techniques and Applications
article

Residual motion artifact removal enables dynamic <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si8.svg" display="inline" id="d1e260"> <mml:mi mathvariant="normal">μ</mml:mi> </mml:math> MRI of a behaving Pachnoda marginata

Mazin Jouda, Ulrike Wallrabe, Jan Gerrit Korvink, Ajmal Chenakkara
article en

Abstract

Microscopic magnetic resonance imaging, also referred to as μMRI, is a non-invasive imaging modality ideal for studying small live model organisms. However, μMRI raw data acquisition is inherently sequential and slow in comparison to the biomechanics timescale of the behaving organism, leading to motion artifacts upon image reconstruction. Recently, we have developed an integrated spherical treadmill with a prospectively triggered k-space acquisition technique to provide position consistency for studying live, behaving insect using μMRI. Despite this advancement, behaving insects on the treadmill still exhibited motion artifacts due to tethered locomotion being coupled with internal organ dynamics. Here, we are addressing the large-scale non-rigid nature of the abdominal motion of the behaving insect by developing a fully retrospective gating strategy using the motion information obtained from an in-situ computer vision system. Residual motion artifacts persisting after gating are effectively managed through a deep learning technique. We trained a U-Net-based deep convolutional neural network using pairs of simulated motion-corrupted and motion-free images as a supervised image-to-image translation problem. Our results demonstrate that combining retrospective gated μMRI reconstruction with a deep learning residual motion compensation technique can significantly reduce the motional artifacts, thereby paving the way for the non-invasive dynamic imaging studies of behaving organisms with 117 μm in-plane resolution.

Journal of Magnetic ResonanceVol. 381
Karlsruhe Institute of Technology (DE), University of Freiburg (DE)
Openalex Percentile: Top 67%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.