Evaluation of the Exail absolute quantum gravimeters AQG-A02 and AQG-B10 by comparison to a precise gravity reference

Abstract We present an evaluation of the novel absolute quantum gravimeters AQG-A02 and AQG-B10 by the French manufacturer Exail with an emphasis on the user's application and outlook for integration into the routine gravity measurements of the German Federal Agency for Cartography and Geodesy (BKG). Since the delivery of these instruments to BKG, test measurements have been performed at the well-established gravity reference stations in Wettzell and Bad Homburg. Our measurements confirm a sensitivity of 500 nm s −2 Hz −1/2 at a quiet site, as specified, equivalent to a precision of 10 nm/s 2 after 1-h integration time, and a combined uncertainty on the order of 100 nm/s 2 , based on a comparison to the local gravity reference function. We conclude that, as of yet, both AQGs do not reach the accuracy of FG5-type gravimeters, but provide advantages for continuous measurements and operation. Despite occasional technical issues with system reliability and pending research on improving the systematic errors, we expect the AQGs will find a central role in BKG's routine gravity measurements in the near future.

Authors

Institutions

Publication Details

Journal
Journal of Geodesy
Published
2025-09-01
DOI
https://doi.org/10.1007/s00190-025-01995-x
Citations
1
Primary Topic
Geophysics and Gravity Measurements
Type
article
Field-Weighted Citation Impact
1.79
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Exail absolute quantum gravimeters AQG-A02 and AQG-B10 by comparison to a precise gravity reference

Hartmut Wziontek, Jan‐Peter Müller, Julian Glässel, Erik Brachmann et al.
1 citations
Journal of Geodesy
Geophysics and Gravity Measurements
1.79
article

Evaluation of the Exail absolute quantum gravimeters AQG-A02 and AQG-B10 by comparison to a precise gravity reference

Hartmut Wziontek, Jan‐Peter Müller, Julian Glässel, Erik Brachmann, Reinhard Falk, Ezequiel D. Antokoletz
article en
1 citations

Abstract

Abstract We present an evaluation of the novel absolute quantum gravimeters AQG-A02 and AQG-B10 by the French manufacturer Exail with an emphasis on the user's application and outlook for integration into the routine gravity measurements of the German Federal Agency for Cartography and Geodesy (BKG). Since the delivery of these instruments to BKG, test measurements have been performed at the well-established gravity reference stations in Wettzell and Bad Homburg. Our measurements confirm a sensitivity of 500 nm s −2 Hz −1/2 at a quiet site, as specified, equivalent to a precision of 10 nm/s 2 after 1-h integration time, and a combined uncertainty on the order of 100 nm/s 2 , based on a comparison to the local gravity reference function. We conclude that, as of yet, both AQGs do not reach the accuracy of FG5-type gravimeters, but provide advantages for continuous measurements and operation. Despite occasional technical issues with system reliability and pending research on improving the systematic errors, we expect the AQGs will find a central role in BKG's routine gravity measurements in the near future.

Journal of GeodesyVol. 99(9)
Federal Agency for Cartography and Geodesy (DE)
Openalex Percentile: Top 14%
Geophysics and Gravity Measurements
1.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of the Exail absolute quantum gravimeters AQG-A02 and AQG-B10 by comparison to a precise gravity reference — Hartmut Wziontek, Jan‐Peter Müller, et al. · Journal of Geodesy (2025) | TGRS Research Map | TGRS