In Pursuit of a Greener Fluorinated Chemical Modifier for the Direct Determination of Rare Earth Elements in Refractory Geological Materials using ETV-ICPOES

Rare earth elements (REEs) have critical industrial and research applications.Accurately determining REEs can be challenging, as these elements are typically found in refractory ore samples.These ores are difficult to dissolve, making analysis via traditional pneumatic nebulization (PN) methods troublesome.For this reason, a solid sample introduction system and a direct analysis method are preferred.In prior studies, electrothermal vaporization coupled to inductively coupled plasma optical emission spectrometry (ETV-ICPOES) has shown promise for the analysis of geological samples.One of the challenges with REEs is that they are prone to carbide formation, which can complicate accurate determination.However, halogenated reagents have been shown to prevent carbide formation and enhance the volatility of analytes.Past work used carbon tetrafluoride (CF4) gas to introduce halogens to the sample.In this work, polytetrafluoroethylene (PTFE) powder was mixed with the sample prior to analysis instead.This study demonstrates that premixing PTFE powder with the sample reduces the relative standard deviations (RSD) compared to individually mixing aliquots in a small graphite boat prior to each replicate measurement.A 5:3 ratio of sample-to-PTFE powder maximized sensitivity.To compensate for sample loading effects on the plasma, an Ar emission line (404.442nm) was used for internal standardization.Given that fluorinated gases can have ozone-depleting effects, using PTFE powder instead of CF4 is much more environmentally friendly.It is also less expensive.Although sensitivity was highest when using CF4 as a chemical modifier for Ce, Er, Gd, Ho, La, Lu, Nd, Sc, Tb, and Y (10 out of 16 REEs), by 3 (Ho) to 19 (Nd) fold versus when using PTFE, the limit of detection (LOD) was lowest when using PTFE powder for Dy, Er, Eu, Ho, Pr, Tm, Y, and Yb (8 out of 16 REEs), by 2 (Er) to 12 (Y) fold, because of a significantly lower background signal than with CF4.

Authors

Publication Details

Journal
Atomic Spectroscopy
Published
2025-09-04
DOI
https://doi.org/10.46770/as.2025.130
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Pursuit of a Greener Fluorinated Chemical Modifier for the Direct Determination of Rare Earth Elements in Refractory Geological Materials using ETV-ICPOES

Diane Beauchemin
Atomic Spectroscopy
Analytical chemistry methods development
article

In Pursuit of a Greener Fluorinated Chemical Modifier for the Direct Determination of Rare Earth Elements in Refractory Geological Materials using ETV-ICPOES

Diane Beauchemin
article en

Abstract

Rare earth elements (REEs) have critical industrial and research applications.Accurately determining REEs can be challenging, as these elements are typically found in refractory ore samples.These ores are difficult to dissolve, making analysis via traditional pneumatic nebulization (PN) methods troublesome.For this reason, a solid sample introduction system and a direct analysis method are preferred.In prior studies, electrothermal vaporization coupled to inductively coupled plasma optical emission spectrometry (ETV-ICPOES) has shown promise for the analysis of geological samples.One of the challenges with REEs is that they are prone to carbide formation, which can complicate accurate determination.However, halogenated reagents have been shown to prevent carbide formation and enhance the volatility of analytes.Past work used carbon tetrafluoride (CF4) gas to introduce halogens to the sample.In this work, polytetrafluoroethylene (PTFE) powder was mixed with the sample prior to analysis instead.This study demonstrates that premixing PTFE powder with the sample reduces the relative standard deviations (RSD) compared to individually mixing aliquots in a small graphite boat prior to each replicate measurement.A 5:3 ratio of sample-to-PTFE powder maximized sensitivity.To compensate for sample loading effects on the plasma, an Ar emission line (404.442nm) was used for internal standardization.Given that fluorinated gases can have ozone-depleting effects, using PTFE powder instead of CF4 is much more environmentally friendly.It is also less expensive.Although sensitivity was highest when using CF4 as a chemical modifier for Ce, Er, Gd, Ho, La, Lu, Nd, Sc, Tb, and Y (10 out of 16 REEs), by 3 (Ho) to 19 (Nd) fold versus when using PTFE, the limit of detection (LOD) was lowest when using PTFE powder for Dy, Er, Eu, Ho, Pr, Tm, Y, and Yb (8 out of 16 REEs), by 2 (Er) to 12 (Y) fold, because of a significantly lower background signal than with CF4.

Atomic SpectroscopyVol. 46(04)
Queen's University, Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 74%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In Pursuit of a Greener Fluorinated Chemical Modifier for the Direct Determination of Rare Earth Elements in Refractory Geological Materials using ETV-ICPOES — Diane Beauchemin · Atomic Spectroscopy (2025) | TGRS Research Map | TGRS