Pb-210 in volume samples: self-attenuation and scattering problems

In this work we study the effect of the matrix of the source on the spectrum and on the full energy peak efficiency for low energy photons. Using realistic simulations carried out with PENELOPE 2018, including detector resolution, we show that small angle Compton scattering does contribute to the peak count rate, implying the dependence of the matrix effects on the linear attenuation coefficient μ and also on the scattering cross section. We show that the effect of Compton scattering can be removed from the apparent peak, resulting a "clean" peak depending only on μ. We apply the procedure for the evaluation of μ on the basis of uncollimated transmission measurements and subsequently use it for the calculation of self-attenuation corrections. We analyze measurements carried out in IFIN-HH in the context of an intercomparison exercise.

Authors

Institutions

Publication Details

Journal
Applied Radiation and Isotopes
Published
2025-09-04
DOI
https://doi.org/10.1016/j.apradiso.2025.112165
Citations
2
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pb-210 in volume samples: self-attenuation and scattering problems

Daniela Gurau, O. Sima
2 citations
Applied Radiation and Isotopes
Radiation Shielding Materials Analysis
1.04
article

Pb-210 in volume samples: self-attenuation and scattering problems

Daniela Gurau, O. Sima
article en
2 citations

Abstract

In this work we study the effect of the matrix of the source on the spectrum and on the full energy peak efficiency for low energy photons. Using realistic simulations carried out with PENELOPE 2018, including detector resolution, we show that small angle Compton scattering does contribute to the peak count rate, implying the dependence of the matrix effects on the linear attenuation coefficient μ and also on the scattering cross section. We show that the effect of Compton scattering can be removed from the apparent peak, resulting a "clean" peak depending only on μ. We apply the procedure for the evaluation of μ on the basis of uncollimated transmission measurements and subsequently use it for the calculation of self-attenuation corrections. We analyze measurements carried out in IFIN-HH in the context of an intercomparison exercise.

Applied Radiation and IsotopesVol. 226
Horia Hulubei National Institute for R and D in Physics and Nuclear Engineering (RO)
Openalex Percentile: Top 22%
Radiation Shielding Materials Analysis
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.