Extractor Solutions Improve the Extraction/Quantification of Microbial Load by Conventional Cultivation Techniques

Limitations in quantifying microorganisms in conventional soil microbiological analyses cause experimental errors. There is a difficulty in performing the correct dilution of the sample, which is influenced by the specific granulometric characteristics of each soil. This study aimed to evaluate different combinations of extracting soil solutions. Clayey loam and sandy loam are the two types of soil evaluated according to current humidity, pH, and granulometric analysis. For the quantification of the Colony Forming Units (CFU g-1) of the soil, extracting solutions of H2O (distilled water), NaCl (sodium chloride), Na4P2O7 (sodium pyrophosphate), and C64H124O26 (Polysorbate Tween-80) were used for analyses. The method of in-depth serial dilution was used in this study to quantify the microorganisms. The means of each microbiological feature were examined and compared using the Tukey test with a 5% chance of being correct. The granulometric characteristics of the soil affected the microbial quantification. The solution of H2O + Na4P2O7 + C64H124O26 allowed greater quantification for sandy loam soils, and for clayey loam soil, the solution of H2O + Na4P2O7 was the most efficient.

Authors

Institutions

Publication Details

Journal
Fronteiras Journal of Social Technological and Environmental Science
Published
2025-09-04
DOI
https://doi.org/10.21664/2238-8869.2025v14i3.7101
Primary Topic
Microbial Community Ecology and Physiology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extractor Solutions Improve the Extraction/Quantification of Microbial Load by Conventional Cultivation Techniques

Osânia Emerenciano Ferreira, Alan Rodrigues Teixeira Machado, Adriana Barboza Alves
Fronteiras Journal of Social Technological and Environmental Science
Microbial Community Ecology and Physiology
article

Extractor Solutions Improve the Extraction/Quantification of Microbial Load by Conventional Cultivation Techniques

Osânia Emerenciano Ferreira, Alan Rodrigues Teixeira Machado, Adriana Barboza Alves
article en

Abstract

Limitations in quantifying microorganisms in conventional soil microbiological analyses cause experimental errors. There is a difficulty in performing the correct dilution of the sample, which is influenced by the specific granulometric characteristics of each soil. This study aimed to evaluate different combinations of extracting soil solutions. Clayey loam and sandy loam are the two types of soil evaluated according to current humidity, pH, and granulometric analysis. For the quantification of the Colony Forming Units (CFU g-1) of the soil, extracting solutions of H2O (distilled water), NaCl (sodium chloride), Na4P2O7 (sodium pyrophosphate), and C64H124O26 (Polysorbate Tween-80) were used for analyses. The method of in-depth serial dilution was used in this study to quantify the microorganisms. The means of each microbiological feature were examined and compared using the Tukey test with a 5% chance of being correct. The granulometric characteristics of the soil affected the microbial quantification. The solution of H2O + Na4P2O7 + C64H124O26 allowed greater quantification for sandy loam soils, and for clayey loam soil, the solution of H2O + Na4P2O7 was the most efficient.

Fronteiras Journal of Social Technological and Environmental ScienceVol. 14(3)
Universidade do Estado de Minas Gerais (BR)
Openalex Percentile: Top 77%
Microbial Community Ecology and Physiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Extractor Solutions Improve the Extraction/Quantification of Microbial Load by Conventional Cultivation Techniques — Osânia Emerenciano Ferreira, Alan Rodrigues Teixeira Machado, et al. · Fronteiras Journal of Social Technological and Environmental Science (2025) | TGRS Research Map | TGRS