Interlaboratory reproducibility of ID-TIMS U–Pb geochronology evaluated with a pre-spiked natural zircon solution

Abstract. The highest precision and accuracy in U–Pb geochronology is achieved using isotope dilution thermal ionisation mass spectrometry (ID-TIMS), a technique which owes its reliability to precise Pb and U isotope ratio analysis, a largely unified framework of lab protocols, and common isotopic tracers with accurately determined compositions. However, while hardware and protocol developments have steadily improved the analytical precision, the level to which ID-TIMS U–Pb dates from different laboratories agree remains largely unquantified. To better assess both internal repeatability and interlaboratory reproducibility of this method, we have conducted an experiment in which a large batch of natural zircon was dissolved, mixed with a newly prepared 205Pb–233U–235U tracer, and distributed as solution to participating laboratories. Thus prepared, pre-spiked, homogeneous PLES535 solution underwent the full sample preparation and analysis process separately in each lab, allowing a maximally unbiased comparison of the entire analytical procedure on a sample of unknown age. The results from 14 instruments at 11 institutions demonstrate internal repeatability of individual labs at 5 to 10 U–Pb analyses, with mean squared weighted deviation (MSWD) values generally indicative of single age populations. Lab weighted-mean 206Pb / 238U and 207Pb / 235U ages for the 337 Ma zircon solution agree within 0.05 % and 0.09 % (2 standard deviations), respectively. This underscores the reliability of the participating laboratories for precise and accurate zircon U–Pb analyses, while highlighting the need for continued exchange on lab protocols and method improvement. We identify likely reasons for the remaining interlaboratory bias and discuss ways forward toward the goal of 0.01 % reproducibility.

Authors

Institutions

Publication Details

Journal
Geochronology
Published
2025-09-04
DOI
https://doi.org/10.5194/gchron-7-409-2025
Citations
3
Primary Topic
Geological and Geochemical Analysis
Type
article
Field-Weighted Citation Impact
5.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interlaboratory reproducibility of ID-TIMS U–Pb geochronology evaluated with a pre-spiked natural zircon solution

Jörn‐Frederik Wotzlaw, Sean P. Gaynor, Simon Tapster, André Navin Paul et al.
3 citations
Geochronology
Geological and Geochemical Analysis
5.60
article

Interlaboratory reproducibility of ID-TIMS U–Pb geochronology evaluated with a pre-spiked natural zircon solution

Jörn‐Frederik Wotzlaw, Sean P. Gaynor, Simon Tapster, André Navin Paul, Joshua H.F.L. Davies, Blair Schoene, Ryan B. Ickert, Michael P. Eddy, Marion Tichomirowa, Corey J. Wall, Dawid Szymanowski, Kevin R. Chamberlain, Albrecht von Quadt, Cyril Chelle-Michou, Urs Schaltegger, Michael T. Mohr, Mark D. Schmitz, James L. Crowley, Alexandra Käßner, Jahandar Ramezani, Maria Ovtcharova
article en
3 citations

Abstract

Abstract. The highest precision and accuracy in U–Pb geochronology is achieved using isotope dilution thermal ionisation mass spectrometry (ID-TIMS), a technique which owes its reliability to precise Pb and U isotope ratio analysis, a largely unified framework of lab protocols, and common isotopic tracers with accurately determined compositions. However, while hardware and protocol developments have steadily improved the analytical precision, the level to which ID-TIMS U–Pb dates from different laboratories agree remains largely unquantified. To better assess both internal repeatability and interlaboratory reproducibility of this method, we have conducted an experiment in which a large batch of natural zircon was dissolved, mixed with a newly prepared 205Pb–233U–235U tracer, and distributed as solution to participating laboratories. Thus prepared, pre-spiked, homogeneous PLES535 solution underwent the full sample preparation and analysis process separately in each lab, allowing a maximally unbiased comparison of the entire analytical procedure on a sample of unknown age. The results from 14 instruments at 11 institutions demonstrate internal repeatability of individual labs at 5 to 10 U–Pb analyses, with mean squared weighted deviation (MSWD) values generally indicative of single age populations. Lab weighted-mean 206Pb / 238U and 207Pb / 235U ages for the 337 Ma zircon solution agree within 0.05 % and 0.09 % (2 standard deviations), respectively. This underscores the reliability of the participating laboratories for precise and accurate zircon U–Pb analyses, while highlighting the need for continued exchange on lab protocols and method improvement. We identify likely reasons for the remaining interlaboratory bias and discuss ways forward toward the goal of 0.01 % reproducibility.

GeochronologyVol. 7(3)
University of Geneva (CH), Boise State University (US), University of Wyoming (US), British Geological Survey (GB), University of British Columbia (CA), Université du Québec à Montréal (CA), Princeton University (US), Purdue University West Lafayette (US), ETH Zurich (CH), TU Bergakademie Freiberg (DE), Massachusetts Institute of Technology (US)
Princeton University, Eidgenössische Technische Hochschule Zürich, Université de Genève
Openalex Percentile: Top 4%
Geological and Geochemical Analysis
5.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.