Assessment of thoracoamniotic shunt catheter patency using pulsed‐wave Doppler and color flow mapping: A case report

Thoracoamniotic shunting is an effective treatment for fetal pleural effusion. Catheter obstruction is a serious and frequently occurring phenomenon that often requires re-shunting; however, accurate diagnosis remains challenging. We present a case in which pulsed-wave Doppler and color flow mapping were used to evaluate fluid flow through a thoracoamniotic shunt catheter. The Doppler assessment revealed alternating fast inflow (median: 69.2 cm/s) and slow outflow (median: 19.0 cm/s) synchronized with fetal breathing movements. Following the cessation of fetal breathing movements, a continuous and steady outflow with a constant velocity was observed. This case highlights the potential utility of Doppler ultrasound in assessing catheter patency, providing valuable information for the diagnosis of catheter obstruction in thoracoamniotic shunting.

Authors

Institutions

Publication Details

Journal
Journal of obstetrics and gynaecology research
Published
2025-09-01
DOI
https://doi.org/10.1111/jog.70040
Primary Topic
Congenital Diaphragmatic Hernia Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of thoracoamniotic shunt catheter patency using pulsed‐wave Doppler and color flow mapping: A case report

Kazuhiko Asai, Ryuichi Shimaoka, Masako Matsui, Shigenori Iwagaki et al.
Journal of obstetrics and gynaecology research
Congenital Diaphragmatic Hernia Studies
article

Assessment of thoracoamniotic shunt catheter patency using pulsed‐wave Doppler and color flow mapping: A case report

Kazuhiko Asai, Ryuichi Shimaoka, Masako Matsui, Shigenori Iwagaki, Yuichiro Takahashi, Hitomi Ono
article en

Abstract

Thoracoamniotic shunting is an effective treatment for fetal pleural effusion. Catheter obstruction is a serious and frequently occurring phenomenon that often requires re-shunting; however, accurate diagnosis remains challenging. We present a case in which pulsed-wave Doppler and color flow mapping were used to evaluate fluid flow through a thoracoamniotic shunt catheter. The Doppler assessment revealed alternating fast inflow (median: 69.2 cm/s) and slow outflow (median: 19.0 cm/s) synchronized with fetal breathing movements. Following the cessation of fetal breathing movements, a continuous and steady outflow with a constant velocity was observed. This case highlights the potential utility of Doppler ultrasound in assessing catheter patency, providing valuable information for the diagnosis of catheter obstruction in thoracoamniotic shunting.

Journal of obstetrics and gynaecology researchVol. 51(9)
Gifu Prefectural General Medical Center (JP)
Openalex Percentile: Top 62%
Congenital Diaphragmatic Hernia Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.