A Substation Image Inspection Method Based on Visual Communication and Combination of Normal and Abnormal Samples

To address the issue of missed detection of abnormal images caused by scarcity of defect samples and inadequate model training that characterize the current substation image inspection methods, this paper proposes a new substation image inspection method based on visual communication and combination of normal and abnormal samples. In this new method, the quality of substation equipment images is first evaluated, and images are recaptured when they are defocused and underexposed. Images are then preprocessed to eliminate the impact of noise on the algorithm. Image feature alignment is then performed to mitigate camera displacement errors that could degrade algorithmic accuracy. Subsequently, normal-labeled images are used to train the model, and a normal sample database is thus established. Built upon visual communication infrastructure with low-level quantization, the visual feature discrepancy between the current inspection images and those in the normal sample database is calculated using the Learned Perceptual Image Patch Similarity (LPIPS) metric. Through this process, the normal images are filtered out while abnormal images are classified and reported. Finally, this new method is validated at a municipal power supply company in China. When the abnormal image reporting rate is 18.9%, the abnormal image reporting accuracy rate is 100%. This demonstrates that the proposed method can significantly decrease the workload of substation operation and maintenance personnel in reviewing substation inspection images, reduce the time required for a single inspection of substation equipment, and improve the efficiency of video-based substation inspections.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-09-04
DOI
https://doi.org/10.3390/en18174700
Primary Topic
Power Line Inspection Robots
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Substation Image Inspection Method Based on Visual Communication and Combination of Normal and Abnormal Samples

Xiang Wan, Zhongyuan Fan, D. Tang, Youbo Liu
Energies
Power Line Inspection Robots
article

A Substation Image Inspection Method Based on Visual Communication and Combination of Normal and Abnormal Samples

Xiang Wan, Zhongyuan Fan, D. Tang, Youbo Liu
article en

Abstract

To address the issue of missed detection of abnormal images caused by scarcity of defect samples and inadequate model training that characterize the current substation image inspection methods, this paper proposes a new substation image inspection method based on visual communication and combination of normal and abnormal samples. In this new method, the quality of substation equipment images is first evaluated, and images are recaptured when they are defocused and underexposed. Images are then preprocessed to eliminate the impact of noise on the algorithm. Image feature alignment is then performed to mitigate camera displacement errors that could degrade algorithmic accuracy. Subsequently, normal-labeled images are used to train the model, and a normal sample database is thus established. Built upon visual communication infrastructure with low-level quantization, the visual feature discrepancy between the current inspection images and those in the normal sample database is calculated using the Learned Perceptual Image Patch Similarity (LPIPS) metric. Through this process, the normal images are filtered out while abnormal images are classified and reported. Finally, this new method is validated at a municipal power supply company in China. When the abnormal image reporting rate is 18.9%, the abnormal image reporting accuracy rate is 100%. This demonstrates that the proposed method can significantly decrease the workload of substation operation and maintenance personnel in reviewing substation inspection images, reduce the time required for a single inspection of substation equipment, and improve the efficiency of video-based substation inspections.

EnergiesVol. 18(17)
Goodyear (United Kingdom) (GB), Sichuan University (CN), UNSW Sydney (AU), Chengdu University (CN), Faculty of Design (SI)
National Key Research and Development Program of China
Openalex Percentile: Top 76%
Power Line Inspection Robots
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.