Time-Dependent Changes in Resorbable Implants for Orbital Wall Fractures: Evaluation Using Orbital Volume Measurements

Resorbable implants are increasingly used in orbital wall fracture reconstruction because of their ability to provide temporary structural support without the long-term complications associated with permanent materials. However, the long-term effects of implant resorption on orbital morphology are unclear. This retrospective study evaluated volumetric changes over time following reconstruction using 2 types of resorbable plates: uncalcined hydroxyapatite/poly-L-lactic acid (u-HA/PLLA) and poly-L-lactic acid/polyglycolic acid (PLLA/PGA). Thirty patients with fresh orbital wall fractures were analysed using computed tomography (CT)-based orbital volume measurements at 3 time points: preoperative, early postoperative, and late postoperative (≥4 mo). Orbital volumes were calculated with Mimics software, and ocular protrusion was assessed to estimate enophthalmos. In the u-HA/PLLA group, the mean orbital volume difference decreased from 2.30±1.29 cm3 preoperatively to 1.10±0.58 cm3 immediately after surgery and remained stable at 1.17±0.63 cm3 during follow-up (P=0.2784 versus early). In contrast, the PLLA/PGA group initially showed improvement, which was followed by significant regression during follow-up periods. A significant correlation was observed between orbital volume differences and enophthalmos (P=0.004, R2=0.260). These findings indicate that PLLA/PGA implants may lead to morphologic regression, whereas u-HA/PLLA provides more stable outcomes. Implant selection should therefore consider long-term mechanical strength to ensure sustained structural integrity and optimal clinical results.

Authors

Institutions

Publication Details

Journal
Journal of Craniofacial Surgery
Published
2025-09-04
DOI
https://doi.org/10.1097/scs.0000000000011895
Citations
1
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time-Dependent Changes in Resorbable Implants for Orbital Wall Fractures: Evaluation Using Orbital Volume Measurements

Nagisa Osa, Yosuke Niimi, Yuki Hasegawa, Ken Masamune et al.
1 citations
Journal of Craniofacial Surgery
Facial Trauma and Fracture Management
2.01
article

Time-Dependent Changes in Resorbable Implants for Orbital Wall Fractures: Evaluation Using Orbital Volume Measurements

Nagisa Osa, Yosuke Niimi, Yuki Hasegawa, Ken Masamune, Hiroyuki Sakurai
article en
1 citations

Abstract

Resorbable implants are increasingly used in orbital wall fracture reconstruction because of their ability to provide temporary structural support without the long-term complications associated with permanent materials. However, the long-term effects of implant resorption on orbital morphology are unclear. This retrospective study evaluated volumetric changes over time following reconstruction using 2 types of resorbable plates: uncalcined hydroxyapatite/poly-L-lactic acid (u-HA/PLLA) and poly-L-lactic acid/polyglycolic acid (PLLA/PGA). Thirty patients with fresh orbital wall fractures were analysed using computed tomography (CT)-based orbital volume measurements at 3 time points: preoperative, early postoperative, and late postoperative (≥4 mo). Orbital volumes were calculated with Mimics software, and ocular protrusion was assessed to estimate enophthalmos. In the u-HA/PLLA group, the mean orbital volume difference decreased from 2.30±1.29 cm3 preoperatively to 1.10±0.58 cm3 immediately after surgery and remained stable at 1.17±0.63 cm3 during follow-up (P=0.2784 versus early). In contrast, the PLLA/PGA group initially showed improvement, which was followed by significant regression during follow-up periods. A significant correlation was observed between orbital volume differences and enophthalmos (P=0.004, R2=0.260). These findings indicate that PLLA/PGA implants may lead to morphologic regression, whereas u-HA/PLLA provides more stable outcomes. Implant selection should therefore consider long-term mechanical strength to ensure sustained structural integrity and optimal clinical results.

Journal of Craniofacial SurgeryVol. 36(7)
Tokyo Women's Medical University (JP)
Openalex Percentile: Top 12%
Facial Trauma and Fracture Management
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Time-Dependent Changes in Resorbable Implants for Orbital Wall Fractures: Evaluation Using Orbital Volume Measurements — Nagisa Osa, Yosuke Niimi, et al. · Journal of Craniofacial Surgery (2025) | TGRS Research Map | TGRS