Calibrations of flat alkali acid phthalate crystals between 650 and 2400  eV using synchrotron radiation

We have developed a dual goniometer end-station using Stanford Synchrotron Radiation Lightsource, beamline 16-2, in the energy range of 650-2400 eV for crystal calibrations. Three alkali acid phthalate crystals [potassium acid phthalate (KAP), rubidium acid phthalate (RbAP), and cesium acid phthalate (CsAP)] with (001) Miller indices are used to demonstrate the capability of our current experimental setup. The beamline provides photon fluxes from about 10<sup>9</sup> to 10<sup>11</sup><i>p</i><i>h</i><i>o</i><i>t</i><i>o</i><i>n</i><i>s</i>/<i>sec</i> between 50 and 2400 eV, with an error less than 1% absolute energy, and energy resolution between 1250 and 1800 depending on the energy. Our crystal calibrations are limited to energies above 650 eV due to our selection of an Amptek 8 µm Be window fast SSD detector. Total reflectivity calibrations of the crystals can be performed by either angle or photon energy scans. Repeatability of rocking curve measurements is better than 2%. Calibration results show significant impacts of Rb L and Cs M absorption edges for reflectivity in this energy range. The results are compared with XOP calculations, a publicly available multi-lamellar (ML) model, with good agreement. This indicates that it is possible to predict performances of flat KAP and RbAP crystals in this energy range when using the ML model.

Authors

Institutions

Publication Details

Journal
Applied Optics
Published
2025-09-04
DOI
https://doi.org/10.1364/ao.567106
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibrations of flat alkali acid phthalate crystals between 650 and 2400  eV using synchrotron radiation

C. Conlon, P. Lake, Wayne C. Stolte
Applied Optics
Advanced X-ray Imaging Techniques
article

Calibrations of flat alkali acid phthalate crystals between 650 and 2400  eV using synchrotron radiation

C. Conlon, P. Lake, Wayne C. Stolte
article en

Abstract

We have developed a dual goniometer end-station using Stanford Synchrotron Radiation Lightsource, beamline 16-2, in the energy range of 650-2400 eV for crystal calibrations. Three alkali acid phthalate crystals [potassium acid phthalate (KAP), rubidium acid phthalate (RbAP), and cesium acid phthalate (CsAP)] with (001) Miller indices are used to demonstrate the capability of our current experimental setup. The beamline provides photon fluxes from about 10<sup>9</sup> to 10<sup>11</sup><i>p</i><i>h</i><i>o</i><i>t</i><i>o</i><i>n</i><i>s</i>/<i>sec</i> between 50 and 2400 eV, with an error less than 1% absolute energy, and energy resolution between 1250 and 1800 depending on the energy. Our crystal calibrations are limited to energies above 650 eV due to our selection of an Amptek 8 µm Be window fast SSD detector. Total reflectivity calibrations of the crystals can be performed by either angle or photon energy scans. Repeatability of rocking curve measurements is better than 2%. Calibration results show significant impacts of Rb L and Cs M absorption edges for reflectivity in this energy range. The results are compared with XOP calculations, a publicly available multi-lamellar (ML) model, with good agreement. This indicates that it is possible to predict performances of flat KAP and RbAP crystals in this energy range when using the ML model.

Applied OpticsVol. 64(28)
Lawrence Livermore National Laboratory (US), Lawrence Livermore National Security (US)
Openalex Percentile: Top 70%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Calibrations of flat alkali acid phthalate crystals between 650 and 2400  eV using synchrotron radiation — C. Conlon, P. Lake, et al. · Applied Optics (2025) | TGRS Research Map | TGRS